Carrier 58EFB Installation, Start-Up, And Operating Instructions Manual page 16

Horizontal induced-combustion sizes 050—125, series 101
Table of Contents

Advertisement

Table 6—Gas Rate Cu Ft/Hr
SIZE OF TEST DIAL
SECONDS
FOR 1
1
2
REVOLUTION
cu ft
cu ft
cu ft
10
360
720
1800
11
327
655
1636
12
300
600
1500
13
277
555
1385
14
257
514
1286
15
240
480
1200
16
225
450
1125
17
212
424
1059
18
200
400
10 0
19
189
379
947
20
180
360
900
21
171
343
857
22
164
327
818
23
157
313
783
24
150
300
750
25
144
288
720
26
138
277
692
27
133
267
667
28
129
257
643
29
124
248
621
30
120
240
600
31
116
232
581
32
113
225
563
33
109
218
545
34
106
212
529
35
103
206
514
36
100
200
500
37
97
195
486
38
95
189
474
39
92
185
462
40
90
180
450
41
88
176
439
42
86
172
429
43
84
167
419
44
82
164
409
45
80
160
400
46
78
157
391
47
76
153
383
48
75
150
375
49
73
147
367
needed (see item 4). Refer to NFGC Appendix F,
Table F-4 for proper orifice sizing at high altitudes.
(2.) High-altitude installations (Canada only)—The Cana-
dian ratings are approved for altitudes up to 2000 ft for
natural and propane gases. High-altitude ratings are
from 2000 ft to 4500 ft above sea level. See Table 7
for nominal burner orifice size. High-altitude input
ratings include a 10 percent derate as required by
Canadian standards.
Table 7—Canadian Orifice Size
SEA LEVEL
GAS
0-2000 FT
Natural
42
Propane
54
h. Proceed to item 3 to adjust manifold pressure.
3. Adjust gas input.
NOTE: The gas valve has been nominally set at 3.5-in. wc for
natural gas.
a. Remove cap that conceals adjustment screw for gas valve
regulator. (See Fig. 15.)
b. Turn adjusting screw either counterclockwise (out) to
decrease input rate or clockwise (in) to increase rate. When
adjusting input rate, DO NOT set manifold pressure less
than 3.2-or more than 3.8-in. wc for natural gas. Make any
major adjustments by changing main burner orifices.
SIZE OF TEST DIAL
SECONDS
FOR 1
5
1
2
REVOLUTION
cu ft
cu ft
50
72
144
51
71
141
52
69
138
53
68
136
54
67
133
55
65
131
56
64
129
57
63
126
58
62
124
59
61
122
60
60
120
62
58
116
64
56
112
66
54
109
68
53
106
70
51
103
72
50
100
74
48
97
76
47
95
78
46
92
80
45
90
82
44
88
84
43
86
86
42
84
88
41
82
90
40
80
92
39
78
94
38
76
96
38
75
98
37
74
100
36
72
102
35
71
104
35
69
106
34
68
108
33
67
33
65
110
32
64
112
31
62
116
30
60
120
HIGH ALTITUDE
2000-4500 FT
43
55
IGNITOR
CONNECTOR
5
cu ft
360
355
346
340
333
PILOT
ADJUSTMENT
327
(UNDER CAP
321
316
SCREW)
310
305
300
PILOT
290
OUTLET
281
273
265
MANIFOLD
PRESSURE
257
250
TAP
243
237
231
225
Fig. 15—Honeywell SmartValve
220
214
209
205
DO NOT redrill orifices. Improper drilling (burrs, out-of-
200
196
round holes, etc.) can cause excessive burner noise and
192
misdirection of burner flames. This can result in flame
188
184
impingement of the burners and heat exchangers causing
180
failures.
178
173
NOTE: If orifice hole appears damaged or it is suspected to have
170
been redrilled, check the orifice hole with the correct size
167
numbered drill bit. Never redrill an orifice. A burr-free and
164
161
squarely aligned orifice hole is essential for proper flame charac-
155
teristics.
150
c. Measure adjusted gas input rate using method outlined in
item 2.
d. Replace cap that conceals gas valve regulator adjustment
screw.
Be sure burner enclosure front is in place after adjustments
have been made.
e. Look through openings in burner enclosure and check
burner flame. The main burner flame should be clear blue,
almost transparent. (See Fig. 16.)
4. Change burner orifice (if necessary).
The furnace is supplied with standard orifices for the gas
shown on rating plate. If orifices need to be changed to
achieve proper input rate, proceed as follows:
a. Remove manifold pipe cover and burner removal cover/air
inlet plate.
b. Remove manifold retention plate.
c. Pull manifold/burner assembly out past support pins and
remove assembly.
NOTE: It is only necessary to remove 1 manifold retention plate
to gain access to burners.
d. Remove burners from assembly and change orifices as
required.
e. Reinstall assembly by reversing the procedure in items a
through d making sure that assembly is securely mounted
under manifold retention plate on opposite side of unit.
16
IGNITION SYSTEM
CONTROL KNOB
IGNITION
MODULE
INLET
PRESSURE
TAP
GAS
PRESSURE
REGULATOR
ADJUSTMENT
(UNDER CAP
SCREW)
A96079

Hide quick links: