Important Ventilation Information Before You Begin - Prestige Pro Line Model Hoods Installation Instructions Manual

Intended for domestic cooking only
Table of Contents

Advertisement

IMPORTANT VENTILATION INFORMATION
BEFORE YOU BEGIN
- PL Model hoods can be ducted to the top or rear. Check product guide for additional
transtions, wall caps, and roof caps.
- Duct size for IBPL600 (600 CFM) is 6" round and an optional tranition model TRC8/6
should be used to increase the duct size to 8" round for optimal performance.
- PL4224 and PL4824 require the use of transition model TR6x15/10RD (NOT IN-
CLUDED) when using the IBPL1200 (1200 CFM) blower.
- All PL hoods have a variable speed blower switch. All PL hoods have a light dimmer
switch.
- See remote or in-line blower installation, depending on your installation application,
instructions before you begin.
NOTE TO INSTALLER: Make sure blowers are free from obstructions (packing
and debris). Test run blowers before finalizing installation. Check with manufac-
turer before attempting to use other than Prestige blower systems. (1-800-358-
8886 for technical information.)
- 4 -