Grate; Molded Brick Panel; Firescreen; Flue Damper - Vermont Castings ASH42 Owner's Manual

Woodburning fireplace
Table of Contents

Advertisement

2. Grate

This fireplace is designed to be used with the supplied
grate or one approved by VCG.
WARNING! Risk of Fire! Use only the factory-sup-
plied integral grate.
• Keeps logs in place.
• Allows proper air circulation around the fire.

3. Molded Brick Panel

The molded brick panel is shipped separately, but
required to contain heat and provide an attractive interior.
It will deteriorate over time and will need occasional
replacement. Small hairline cracks and discoloration
are normal and do not affect its safety.
Cracks in the mortar may occur and do not affect the
safety of the fireplace.
(See Molded Brick Panel Maintenance, Section 4.F.)
WARNING! Risk of Fire! DO NOT burn fireplace with-
out molded brick panel. Use only panels supplied by
Vermont Castings Group.

4. Firescreen

The firescreen is provided to control sparks. Keep it
closed when the fireplace in use.
WARNING! Risk of Fire or Burns!
• Screen will not prevent burning materials from falling
out.
• Screen pulls or handles may be hot.

5. Flue Damper

The flue damper must be in the fully opened position
during operation of the fireplace.
WARNING! Risk of Fire and Asphyxiation! Open
damper prior to operating fireplace. A closed damper
overfires the fireplace and spills smoke and flames
into the room.

6. Glass Doors

Glass doors are optional.
WARNING! Risk of Fire! Install ONLY doors approved
by Vermont Castings Group.
WARNING! Risk of Fire and Smoke! Fireplace
equipped with doors should be operated only with
doors fully open or doors fully closed. If doors are left
partly open, gas and flame may be drawn out of the
fireplace opening.
8
VCG Ashland Series • ASH42 OWNERS MANUAL • 4059-916 • Rev A • 2/20/15

7. Over-Firing Your Fireplace

WARNING! Risk of Fire! Do not over-fire.
Over-firing may ignite creosote or will damage the
fireplace and chimney.
To prevent over-firing your fireplace. DO NOT:
• use flammable liquids
• overload with wood
• burn trash or large amounts of scrap lumber
• permit too much air to the fire
Symptoms of over-firing may include one or more of the
following:
chimney connector or fireplace glowing
roaring, rumbling noises
loud cracking or banging sounds
metal warping

chimney fire

8. Chimney Fire
In the event of a chimney fire
Have the chimney and adjacent structure inspected
by qualified professionals. Vermont Castings Group
recommends that NFI or CSIA certified professionals,
or technicians under the direction of certified
professionals, conduct a minimum of an NFPA 211
Level 2 inspection of the chimney.
Replace components of the chimney and fireplace
as specified by the professionals.
Ensure all joints are properly engaged and the
chimney is properly secured.
WARNING! Risk of Fire! A chimney fire can perma-
nently damage your chimney system. Failure to re-
place damaged components and make proper repairs
can cause a structure fire.