Installation Guide for areas exposed to sea wind
CAUTION
1. Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced.
2. Do not install the product where it could be exposed to sea wind (salty wind) directly. It can result corrosion
on the product. Corrosion, particularly on the condenser and evaporator ns, could cause product malfunc-
tion or ine cient performance.
3. If outdoor unit is installed close to the seaside, it should avoid direct exposure to the sea wind. Otherwise it
needs additional anticorrosion treatment on the heat exchanger.
Selecting the location(Outdoor Unit)
1) If the outdoor unit is to be installed close to the seaside, direct exposure to the sea wind should be avoided.
Install the outdoor unit on the opposite side of the sea wind direction.
Sea wind
2) In case installation of the outdoor unit on the seaside is unavoidable set up a windbreak so the outdoor unit is
not exposed to the sea wind.
Windbreak
Sea wind
3) Select a well-drained place.
1. If you can't meet above guide line in the seaside installation, please contact LG Electronics for the additional anticorrosion treatment.
2. Periodic ( more than once/year ) cleaning of the dust or salt particles stuck on the heat exchanger by using water
82
Sea wind
• The windbreak should be strong enough to prevent
the sea wind from the sea.
• The height and width should be more than 150% of
the outdoor unit.
• It should have more than 700mm (27 19/32 inch) of space
between outdoor unit and the windbreak for easy
air ow.