Preface; Electronic Type; Mechanical Type - LG C6000 Service Manual

Room air conditioner
Table of Contents

Advertisement

Preface

SERVICE MANUAL
This
etc. This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.

Electronic Type

1. Unplug the power cord and connect a jumper between 2 pins (black and white).
2. The grounding conductor (green or green and yellow) is to be open.
3. Measure the resistance value with an ohm meter between the jumpered lead and each exposed metallic part on
the equipment at all Mode [except POWER OFF].
4. The value should be over 1MΩ.

Mechanical Type

1. Unplug the power cord and connect a jumper between 2 pins (black and white).
2. The grounding conductor (green) is to be open.
3. Measure the resistance value with an ohm meter between the jumpered lead and each exposed
metallic part on the equipment at all the positions (except OFF) of the ROTARY SWITCH.
4. The value should be over 1MΩ.
provides various service information, including the mechanical and electrical parts
Preface
Service Manual 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents