GENERAL INSTALLATION GUIDELINES

Location Selection

DANGER
To avoid the possibility of fire, do not install the unit in an area where combustible gas may generate, flow, stagnate, or leak. Installing the unit in
an area containing combustible gas will cause serious bodily injury or death. Before beginning installation, read the safety summary at the beginning
of this manual.
Select a location for installing the Art Cool Mirror wall-mounted indoor unit (IDU) that meets the following conditions:
• Where there is enough structural strength to bear the weight of the unit.
• Where air circulation will not be blocked.
• Where noise prevention is taken into consideration.
• Ensure there is sufficient space from the ceiling and floor.
• Locate the indoor unit in a location where it can be easily connected to the outdoor unit / branch distribution unit.
• Include space for drainage to ensure condensate flows properly out of the unit when it is in cooling mode.
• Use a level indicator to ensure the unit is installed on a level plane.
Note:
The unit may be damaged, may malfunction, and / or will not operate as designed if installed in any of the following conditions:
Do not install the unit where it will be subjected to direct thermal radiation from other heat sources.
Do not install the unit in an area where combustible gas may generate, flow, stagnate, or leak.
Do not install the unit in a location where acidic solution and spray (sulfur) are often used.
Do not use the unit in environments where oil, steam, or sulfuric gas are present.
Do not install additional ventilation products on the chassis of the unit.
Do not install the unit near high-frequency generator sources.
Do not install the unit near a doorway.
Installing in an Area Exposed to Unconditioned Air
In some installation applications, areas (floors, walls) in some rooms may be exposed to unconditioned air (room may be above or next to an
unheated garage or storeroom). To countermeasure:
• Verify that carpet is or will be installed (carpet may increase the temperature by three degrees).
• Add insulation between the floor joists.
• Install radiant heat or another type of heating system to the floor.
Required Clearances
Figure 6 shows required clearance distances around a typical installed wall-mounted unit.
18
Figure 2: Required Clearances Around Typical Installed Unit
More than 4
At least 6.5 from the floor
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
9/12/18k Indoor Units: ≥5
More than 4
Unit: Inch