8 | Regulations

Technical characteristics
Temperature selector in fully anti-clockwise position
Temperature rise (Above incoming water temperature)
Water flow range (Litres per minute)
Minimum operating water pressure
Minimum constant water pressure for maximum flow
Table 5
3
Regulations
All local by-laws and regulations pertaining to installation and
use of gas appliances must be observed.
This appliance must be installed in accordance with the
manufacturers installation instructions, AS/NZS5601, AS/
NZS3500 and all Local Building & Gas fitting regulations.
This appliance must not be installed indoors or in an enclosed
space. This appliance is approved for outdoor installation only.
Do not install this appliance with any modification or alteration.
Failure to install this appliance in accordance with these
installation instructions will void the warranty and may create
an unsafe situation.
4

Installation

DANGER:
This appliance must not be installed indoors
or in an enclosed space in accordance with
AS/NZS5601.
DANGER: Explosion Risk!
▶ Always turn off the gas valve before
carrying out any work on components
which carry gas.
DANGER: Appliance malfunction!
This appliance must be installed with no
obstructions to air entry openings at the
front, rear, side, or top.
▶ Periodic checking of openings to ensure
no blockage or obstruction of the air
openings from plants, debris, or insects
must be carried out.
8 716 473 071 (2015/04)
Units
TF250H / 10H
°C
25
l/min
4 to 10
kPa
45
kPa
100
NOTICE: Property damage!
If the appliance is to be installed on a
combustible surface:
▶ Use a heat shield as per AS/NZS5601 -
accessory
9 708 061 400.ZG1 ( Fig. 4).
=
Fig. 4
Heat shield
The installation and the initial startup are to
be carried out only by an authorised person.
Not suitable for pool, spa pool, or solar
booster application.
Not suitable for commercial boosting of a
warm water recirculation system.
This appliance should only be installed in
applications where incoming cold water
temperature does not exceed 40 °C.
TF325H / 13H
TF400H / 16H
25
25
4 to 13
4 to 16
45
45
140
170
850 mm
=
9708069951-12.1V
HydroPower

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hydropower tf325-8g(13h)Hydropower tf400-8g(16h)

Table of Contents