Environmental Protection - Bosch HydroPower TF250-8G(10H) Installation Manual And Operating Instructions

Table of Contents

Advertisement

Problem
Reduced water flow.
Unit makes a loud bang when igniting.
Presence of soot/black marks observed at
top of flue / on wall.
Water takes a long time to reach hot taps. Location of unit.
Table 10
9

Environmental protection

Environmental protection is a basic company strategy of
Bosch. The quality of our products, profitability and
environmental protection are equal-ranking goals for us. Laws
and regulations concerning environmental protection are
strictly observed. We use the best possible technology and
materials, under economic considerations, to protect the
environment.
Packaging
We participate in the recycling program of the respective
country to ensure optimal recycling. All of our packaging
materials are environmental-friendly and can be recycled.
HydroPower
Cause
Insufficient water supply pressure.
Dirty taps or mixers.
Water valve blocked (filter).
Heat exchanger blocked (limescale).
Explosive ignition is not normal
behaviour.
This is not normal behaviour.
This is normally caused by blockages in
the burner causing poor combustion.
One of the causes of blockages is insects
blocking burner orifices, this cannot be
avoided as adequate air flow is required
for complete combustion.
Old appliances
Old appliances contain valuable materials that should be
recycled.
Environmental protection | 17
Solution
Requires a service technician to inspect
and test water supply pressures, and
water components of the hot water unit.
Call a qualified technician.
All gas appliances require adequate air
flow for proper combustion. The ingress
of insects or dirt into the unit are not
covered by warranty as a manufacturing
fault is not present. The unit will need
cleaning and servicing at the owners' cost.
To minimise the chance of the issue
recurring, a surface type insecticide can
be used with care, consultation with a
licensed pest controller is recommended.
Isolate the valves to the unit and spray
surrounds with a surface spray.
Leave for 15 minutes before turning hot
water on.
If the unit is located a long way from the
outlet there will be an amount of cold
water that has to leave the pipe before the
hot water is available. As the hot water
unit does not operate at a large flow rate
this may appear to take a long time,
particularly if it has replaced a mains
pressure storage heater.
Open hot tap to full to increase flow rate
and reduce time.
8 716 473 071 (2015/04)