Majestic fireplaces CVR36 Homeowner's Installation And Operating Manual page 10

Str series; cvr series
Hide thumbs Also See for CVR36:
Table of Contents

Advertisement

STR/CVR Series Woodburning Fireplaces
Actual Centerpoint
Chimney
Centerline
 MODEL
STR 33:
STR36 / CVR36: 20�/�" 521mm)
STR42 / CVR42: 23�/�" (597mm)
Fig. 10 Locate centerline of chimney with plumb line.
Ceiling Chimney Hole/
Possible Obstructions
FP707
The size of the hole in ceiling will vary with the angle at
STR/CVR
which the chimney passes through ceiling.
LOCATE CENTER LINE
6/1/98
Drive a nail up through ceiling at marked chimney cen-
ter point. Go to floor above and see where hole will be
cut. Check to see where existing ceiling joists and other
possible obstructions are located...i.e. wiring, plumbing
etc... If necessary, re-position chimney and/or fireplace
to avoid obstructions.
Cutting the Hole
Cover fireplace collar opening and cut proper sized
chimney hole in chimney. The SK8 pipe allows you to
run pipe through a typical 16" on center joist without
cutting joists.
10
X
Side of
STR/CVR
Plumb Line
Plumb Bob
Imaginary
Centerpoint
X =
19" (483mm)
FP707
Framing the Ceiling Hole
Frame the ceiling chimney hole as shown in Figure
12. It is good practice to use framing lumber that is the
same size as the ceiling joists; this is a requirement at
attic level.
The following table gives firestop spacer model num-
bers:
Angle of Chimney at Ceiling
Size of Chimney
Vertical
8" Flue
SKFS2A
"SK" Series
14¹⁄₂" x 14¹⁄₂"
(368mm x 368mm) (368mm x 648mm)
11" CF 2-Wall
17¹⁄₂" x 17¹⁄₂"
(445mm x 445mm) (454mm x 753mm)
Fig. 11 Ceiling chimney hole sizes necessary for installing
firestop spacer.
The inside dimension of the frame must be the same
as the hole size selected from Figure 12 in order to
provide the required air space (1¹/₂" (38mm)with SK8,
2" (51mm) with Model 11CF) between the outside
diameter of the chimney and the edges of the framed
ceiling hole.
Existing
A/B
Ceiling
Joists
New Framing
Members
A "SK8" Series framing = 14���" X 14���" (368 x 368mm)
B 11CF framing = 17���" X 17���" (445 x 445mm)
Fig. 12 Typical frame for ceiling chimney hole.
FP551A
BR/BC
9/23/98
30°
SKFS6A
14¹⁄₂" x 25¹⁄₂"
FS2A
FS6A
17⁷⁄₈" x 29⁵⁄₈"
A/B
Chimney Hole
FP551A
7412961

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cvr42Str33Str36Str42Str33Str36 ... Show all

Table of Contents