Hide thumbs Also See for CDX-601:
Table of Contents

Advertisement

Note:
Power supply voltage: DC14.4 V (more than 3 A).
• FOCUS BIAS CHECK
– RF BOARD –
(Component Side)
oscilloscope
+
TP (VC)
IC101
TP
(RFO)
Procedure:
1. Connect the oscilloscope to TP (RFO) and TP (VC) on the RF
board.
2. Put the set into play mode by loading the disc.
3. Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
Note:
Clear RF signal waveform means that the shape "◊" can be clearly distin-
guished at the center of the waveform.
RF signal waveform
14
SECTION 6

ELECTRICAL CHECK

• TRACKING OFFSET CHECK
– RF BOARD –
Procedure:
1. Connect the oscilloscope to TP (TE) and TP (VC) on the RF
2. Put the set into play mode by loading the disc.
3. Press the . AMS > button, and check the traverse wave-
4. Confirm that the oscilloscope waveform is symmetrical on the
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level: 1.4 ± 0.3 Vp-p
(Component Side)
oscilloscope
+
TP (VC)
IC101
TP (TE)
board.
form*.
top and bottom in relation to 0 V dc, and check this level.
* Traverse waveform: This is the tracking error wave form appears
when crossing the track.
Traverse waveform
A
0 V
B
A=B
traverse waveform
(100 track jump waveform)
VOLT/DIV : 500 mV
TIME/DIV : 2 ms
Center : 0 V

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdx-636

Table of Contents