Color Performance and Contrast
Test Signal : 854x480@60Hz
Test Pattern : 64 RGBW scale Pattern and Gray 16 Pattern
*
Please check and ensure if each color is normal and distinguishable
*
If not, please return the unit to repair area.
-
Screen Uniformity
Test Signal : 854x480@60Hz
Test Pattern : Full White Pattern
*
Please check and ensure the unit is under the spec. (Pixel number should be smaller or
amount to 6 pixels.)
*
Please check and see if it's in normal condition.
*
If not, please return the unit to repair area.
-
Dead Pixel (Bright/Dark pixel)
Test Signal : 854x480@60Hz
Test Pattern : Full Black Pattern and Full White Pattern
*
Please check and see if there are dead pixels on DMD chip
*
The total numbers and distance of dead pixels should be complaint with the spec.
Notice :
(1)
(2)
-
Light Leak
Test Signal : 854x480@60Hz
Test Pattern : Gray 10 Pattern
*
Please check and see if the light leaks*Notice
*
The unit cannot accept the leakage is brighter than Gary 10 pattern
Notice : light leak on reflective edge, eyecatcher, bond wires and exposed metal.
-
ECO Mode
Test Signal : 854x480@60Hz
Test Pattern : Gray Scale Pattern
*
Press "Menu" and choose "Brite" function
*
When choose "On", the screen will become darkness.
*
When choose "Off", the screen will resume normally.
-
Connect the signal
-
Choose "Video Calibration" function
Bright Pixel :
Test Pattern : Full Black Pattern
-
Please check and ensure that the unit cannot accept any bright pixel.
-
If not, please return the unit to repair area.
Dark Pixel :
Test Pattern : Full White Pattern
-
Please check and ensure that the pixel number should be smaller or
amount to 6 pixels
-
If not, please return the unit to repair area.
4-7