Setion Viii: Electrical Connections - Bradford White UCG100H199 Installation & Operation Manual

Gas-fired commercial water heater
Table of Contents

Advertisement

Turn off or disconnect the electrical power supply to the water heater before servicing. Label all wires prior to
disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper
operation after servicing.
All electrical wiring must be installed and grounded in accordance with local codes, or in the absence of local codes, the
National Electrical Code, ANSI/NFPA 70 and/or CSA C22.2 Electrical Code.
The water heater must be wired to a 120 VAC, 60 Hz, 15A power supply. The water heater must be wired on a separate
circuit and breaker. If a flexible line cord and plug is permitted by local code, then provide a three wire grounding type
receptacle within reach of the line cord provided on the control box. Do not plug the line cord into a receptacle that can
have the power supply interrupted by a switch that is used to control lights or another appliance.
If wiring in conduit is required, cut the line cord close to the control board and make the appropriate wiring connections.
Install an electrical conduit connector on the outside jacket of the water heater. Refer to the wiring diagram for the correct
connections to each wire lead.
This water heater must be wired on a separate circuit. Failure to wire on a separate circuit may cause improper
operation or failure of the electrical components of the water heater. Refer to the "Electrical Connections" section of the
Installation and Operating Instructions Manual for complete instructions on electrical wiring and connections to the water
heater.
Do not energize the electric circuit before the water heater tank is filled with water.

SETION VIII: ELECTRICAL CONNECTIONS

Figure 9. Wiring Diagram and Schematic.
WARNING
CAUTION
25