D. EMW330 ONLY Change the viewing direction. If the Z-axis adjustment above
points the lens toward the side of the housing, the IR LEDs and light sensor must be
repositioned. Here, the IR LEDs are at factory/end position. To change them to the
side position:
1. Remove the
detach the IR
bracket from
2. Replace the factory light sensor "end" bracket by the light sensor "side" bracket:
Remove the 2 screws from the light sensor "end" bracket.
4 screws as shown in figure to
LED panels and light sensor upper
the camera cover.
- 7 -