7.
Tighten the screws that secure the
lamp.
Loose screw may cause a bad
connection, which could result in
malfunction.
Do not over tighten the screws.
8.
Ensure the handle is fully laid flat and
locked in place.
9.
Replace the lamp cover by sliding it
into place.
10. Tighten the screw that secures the
lamp cover.
Loose screw may cause a bad
connection, which could result in
malfunction.
Do not over tighten the screw.
11. Restart the projector.
Do not turn the power on with the lamp cover removed.
Resetting the lamp timer
12. After the startup logo, open the On-
Screen Display (OSD) menu. Go to the
SYSTEM SETUP: Advanced > Lamp
Settings menu. Press Mode/Enter. The
Lamp Settings page displays. Press
highlight Reset lamp timer and press
Mode/Enter. A warning message displays asking if you want to reset the lamp
timer. Highlight Reset and press Mode/Enter. The lamp time will be reset to
'0'.
Do not reset if the lamp is not new or replaced as this could cause damage.