Safety Precaution Safety precaution Installation For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized service center. Do not disassemble or repair the product by yourself. Sharp edges could cause injury, be especially careful of the case edges and the fins on the condenser and evaporator.
Specification Replace the all batteries in the remote control with new ones of the same type. Do not mix old and mew batteries or different types of batteries. Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire. If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water.
Page 6
Specification 2 Specification Model AMC-15A Nameplate marking Power supply Ph-V-Hz 1φ,220V~240V,50Hz Cooling Capacity 4400 Cooling Power consumption 1700 Heating Power consumption 1500 Cooling Rated current Cooling SCE 2.61 System data Refrigerant type R410A/605g Operation pressure L/DAY Moisture Removal(30 ,RH80%) ℃...
Display Display LED display 1. POWER Press this button to switch the unit on or off 2. FUNCTION Press this button to select between Cooling ( ), Heating ( ) or Dehumidifying ( ) mode 3. TEMP+ Pressing this button in cooling mode adjusts the required room temperature by 1°C up to a maximum temperature of 30°C.
Page 9
Display (Automatic)”. If “AUTO” is selected, the ventilator operates at temperature differences larger than 9 degrees at top speed. If the temperature reduces to a difference smaller than 4 degrees, the ventilator switches to middle blower position. If the temperature reduces further until the target temperature, the ventilator switches to the lowest blower position.
Refrigerant cycle diagram Refrigerant cycle diagram The figure below is a brief description of the important components and their function in what is called the refrigeration system...
Feature Unit Disassembly sequence Step1 Casing Disassembly disassemble hot and cool air louver and unscrew the casing of front panel,side panel and top panel screws screws disassemble Filter and unscrew screws...
Feature Step2 Internal Parts Disassembly Motor and PCB Disassembly: please also dismantle the screws at two sides,for the right side is the fasten strip screws Disassembly steps for water motor : please dismantle the screws of condensor,slide up the partition panel.and then slow take out the condensor from the left hand side.From there, you can see the water motor.Caution, please be note that in order to avoid any water split by water wheel, you should uphold the condensor screws...
Page 16
Characteristic of temperature sensor Characteristic of temperature sensor...
Electronic function Electronic function 10.1 Function 10.1.1 Cooling , Heating or Dehumidifying mode 10.1.2 With Auto switch on, off and sleep mode function 10.1.3 Ts range:Cooling:17~30℃/65~90°F;Heating:15~25℃/60~80°F; Time delay safety control 10.1.4 With 3 fan speed mode available in high, medium, low for the upper fan system while for the lower fan system is only available with single speed.
Page 18
Electronic function A: Under the condition of T1≥T +1℃(2°F),compressor will be running B:Under the condition of T1≤T +1℃(2°F),the unit will be switched off,compressor will be off too C:Under the condition of T1≤T +1 (2°F),the compressor and internal motor system ℃ will be switching back to the original setting Note: When compressor is off, cooling operation light is splashing(0.5second per time)When the compressor is running, the operation light will be turned on...
Electronic function B. Under the condition of T3-T1≤-1℃(2°F)compressor will be turned off C. Under the condition of T1=T3-1℃(2°F)compressor will be operated under the original setting mode Note: Under the condition of compressor off. Heating light is splashing (0.5second per time) compressor will be running and heating indication light will be turned on.
Page 20
Electronic function system will be off. All the power will be off. Signal will be turn into E4. If the water full signal is off., the control system has to be pressed on or off to restart the operation 10.8.4 E1:indicate the indoor temperature hot and resistance is in error thus control system will be off. 10.8.5 E2:indicate the indoor temperature hot and resistance is in error thus control system will be off.
Basic test procedure Basic test procedure 11.1 Defective compressor Compressors are single phase, 115 or 120 volt, depending on the model unit. All compressor motors are permanent split capacitor type using only a running capacitor across the start and run terminal.
Basic test procedure If test shows: A. Below normal high side pressure. B. Above normal low side pressure. C. Low temperature difference across coil. The compressor valves are faulty - replace the compressor. 11.1.4 Terminal overload (external) Some compressors are equipped with an external overload which is located in the compressor terminal box adjacent to the compressor body The overload is wired in series with the common motor terminal.
Page 23
Basic test procedure 5. Vacuum Pump (capable of 200 microns or less vacuum.) 6. Acetylene Welder 7. Electronic Halogen Leak Detector (G.E. Type H-6 or equivalent.) 8. Accurate refrigerant charge measuring device such as: a. Balance Scales - 1/2 oz. accuracy b. Charging Board - 1/2 oz.
Basic test procedure small increments while operating the unit. 12. Restart unit several times after allowing pressures to stabilize. Pinch off process tubes, cut and solder the ends. Remove pinch off tool, and leak check the process tube ends. 11.2.4 Special procedure in the case of compressor motor burnout.
Basic test procedure 4. Apply "live" test cord probes on red wire and common terminal of capacitor. Motor should run at low speed. 5. Apply "live" test cord probes on each of the remaining wires from the speed switch or system switch to test intermediate speeds.
Trouble shooting Trouble shooting PROBLEM POSSIBLE CAUSE REMEDY Check the power supplier if the power supplier is supplied to the Power failure unit. Check the power cord and correct if damaged. No power display Check resistance between the two input/output lines on on panel or any one Transformer (Discharge transformer.
Page 28
Trouble shooting Check the temperature setting if not at the coolest (in cooling Room temp sensor mode) or the warmest (in heating mode). Set it if not. Check the compressor for open circuit or ground. If open or Compressor grounded, replace the compressor. Remove the cabinet and carefully rearrange tubing not to Excessive noise.
Trouble shooting Trouble shooting problems no signal Power source Power cord Replace proble damged Water full light on Check main pCB Repair and replacement Abnormal Control Abnormal dipslay Check if water full Water drainage or not Connection Micro switch Water full after Water pump problem between problem...
Trouble shooting Trouble shooting for electrical system unit not running With E1 signal compressor off With E1 signal compressor off Fan coil damaged Plug in Power source Power source Sensor wire off Plug 120V Senor of fan coil replacement damaged Transformer 120V Temperature sensor replac...