GENERAL
Tank Temp.
Brew at Temp.
Units of Meas.
Logo Timeout
Brew B. Sensor
INPUTS
Display Inputs
Cal. Touch Scr
BREW AT TEMPERATURE DEFINITONS
BREW AT TEMP: AUTO
(DEFAULT: FACTORY PROGRAMMED INTO BREWER)
This allows the "BREW START" to active. If the hot water
tank is at the selected temperature—the brew will start.
If the temperature is too low, the brewer will wait until the
proper temperature is reached. A screen (example to the
right) will display showing a thermometer icon and the tank
temperature.
IMPORTANT: ALWAYS have dispenser(s) under the brew
baskets when in the BREW AT TEMP mode.
BREW AT TEMP: ON
"BREW START" Batch Section Buttons will not be
accessible until tank temperature is at set point.
The "BREW START" screens with the Batch Section
Buttons become accessible when hot water tank is at the
selected temperature. The screen at right displays when
the "BREW AT TEMP" is selected.
BREW AT TEMP: OFF
Allows brewing at any temperature above 179°F/82°C. (Not recommended)
.
Programming
Factory set
Items
Default
200°F
"OFF" allows
AUTO
brewing at any
temperature.
• Temperature
°F
• Volume
Liters
1:00 mm:ss
NORMAL
Programming
Factory set
Items
• Input
Summery
Calibrate
USER SELECTABLE
USER SELECTABLE
Programming Range
|______________[]___|
180
|____________[]___|
OFF
|___[]____________|
|_____________[]__|
Gallons
|_[]_______________|
0:00
|__[]____________|
NORMAL
Programming Range
Default
Brew Basket Sensor
High Liquid Level probe
High Tank Temperature Probe
Lower Tank Temperature Probe
SD Card Recognized
USB Drive Recognized
________________[]____
YES
13
(display)
200 °F
Correction for high
207
AUTO
SEE NOTE BELOW!
ON AUTO
°F
°F
°C
Liters
Liters
1:00 mm:ss
5:00
NORMAL
OVERRIDE
(display)
Calibrate
Follow directions on
NO
Chart to correct for boiling point for altitude
in tank water temperature.
Suggested
Altitude (ft.)
Setting(°F)
0
200
500
200
1000
200
2000
200
2500
200
3000
200
3500
197
4000
195
4500
194
5000
194
5500
193
6000
192
6500
191
7000
190
7500
188
8000
187
Notes
altitude below
Notes
USB is for factory
setup only
If Yes:
the touch screen
Boiling
point (° F)
212.0
211.1
210.2
208.4
207.5
206.6
205.7
204.8
203.9
203.0
202.0
201.1
200.2
199.3
198.3
197.4

Hide quick links: