Chain Link Fault Items
116
741 Form registration error
116
742 Logo registration error
116
743 Form/Logo size over flow
116
745 ART Command Error
116
746 Form composition error
Conditions of detect/Methods of treatment
When registering the form, it is not available to register due to the
limitation of the number of registration.
With referring the handling manual, delete unnecessary ones after
checking the registered form.
Or delete the unnecessary forms by the print command.
When registering the logo data, it is not available to register due to the
limitation of the number of registration.
With referring the handling manual, delete unnecessary ones after
checking the registered logo.
Or delete the unnecessary logos by the print command.
The received data (form /logo) is over te registered buffer size.
With referring the handling manual, add the memory size of form
registration area in the memory setting.
Or install HDD.
An error is caused to ART command.
Check the print data, delete the command to cause the error, and
execute printing again.
The specified form is not registered.
Use the registered form, or register the required form.