Venting The Dryer - LG DLEX3370 series Owner's Manual

Hide thumbs Also See for DLEX3370 series:
Table of Contents

Advertisement

Available languages

Available languages

20
NSTALLATION
INSTRUCTIONS
Venting
the Dryer (cont.)
Ductwork
Recommended
(10,2 cm)
(10.2 c:m)
Use only for
short run
installations
o
I
2
3
4
o
I
2
3
4
65 ft, (19,8 m)
55 ft. (16.8 m)
47 ft. (14.3 m)
36 ft. (11,0 m)
28 ft. (8.5 m)
55 ft. (16.8 m)
47 ft. (14.3 m )
41 ft. (12.5 m)
30 ft. (g.1 m)
.................
@ NOTE
-,
Deduct 6 ft, (I .8 m) foreach additional elbow, itisnot
recommended
to use more than four90°elbows.
ROUTING AND CONNECTING DUCTWORK
r _-- _ NOTE
.......................................................................
Followthe guidelines below to maximize drying
performance and reduce lint b uildup and
condensation in the ductwork
Ductwork and fittings are NOT includedand must be
purchased separately.
•Use 4-inch(I02 cm) diameter rigid or semirigid
metal ductwork,
•The exhaust duct run should be as shortas possible.
• Use as few elbow joints as possible.
• The male end of each section of exhaust duct must
point away from the dryer.
• Use duct tape on all duct joints.
• Insulate ductwork
that runs through
unheated
areas
in order to reduce condensation
and lint buildup
on
duct surfaces.
• Failure to exhaust the dryer correctly
will void the
dryer's warranty.
\__J
CORRECT VENTING
INCORRECT VENTING