Part 10 Installation

1. Installation place

● A place where there is enough room for installation and maintenance.(Refer to Chart 1)
● The ceiling is structurally sound to hold the Indoor Unit.
● A place that is well ventilated and the influence of weather is the least.
● A place that the airflow can reach every corners of the room.
● A place where the drain pipe can reach out easily.
●Install the outdoor unit on a rigid base to prevent increasing noise level and vibration.
●Determine the air outlet direction where the discharged air is not blocked.
●In the case that the installation place is exposed to strong wind such as a seaside or high position, secure the
normal fan operation by putting the unit length wise along the wall or using a duct or shield plates.
●Specially in windy area, install the unit to prevent the admission of wind.

2. Indoor unit installation

Adjust the indoor unit and the ceiling hole with Installation Model Paper applied. Fix the Model Paper on the
main body of the air conditioner with five screws (M4x16) applied.
1. Installing φ10 hanging screw bolt. (4 bolts)
2. Overhanging the Indoor unit
Note: Do not lean the air conditioner when overhanging it because drain pump and water lever switch are
installed inside.
Adjust the gasket (down side) to 137mm over the ceiling.
Refrigerant Pipe
100mm
above
Ceiling
Chart 1
Hanging Bolt
Nut (Up Side)
Gasket
Installing Ear
Gasket (Down Side)
Nut (Down Side)
Down Side of the ceiling
17
100mm
above
245mm
above
200mm
above