Changing the needle
Turn off the electrical power
To remove: Lower the presser foot and move
the needle(s) to the highest position by turning
the handwheel towards you. Push the needle
inserting tool (from the accessory box 47) from
below upward fully over the needle. Loosen the
fastening screw of the needle (without remo-
ving it) with the Allen key (behind the swivel
plate) and pull the needle down to remove.
To insert: Insert the needle into hole E of the
needle inserting tool, so that the fl at needle
shank K faces the fl at side L of the inserting
tool. Insert the needle fully into the holder
and tighten the fastening screws. Remove the
needle inserting tool.
Overlock needles types EL X 705, cat. no. 2002
are required for this machine.