Sony MZ-NF520D Service Manual page 25

Portable minidisc player
Hide thumbs Also See for MZ-NF520D:
Table of Contents

Advertisement

• Adjustment Method of CD and MO Overall Adjustment
Mode
1. Set the test mode (see page 13).
2. Press the
key to activate the overall adjustment mode.
.
Set LCD display
000
A s s y 1 1
3. Insert CD disc in the set, and press the
CD overall adjustment mode. Automatic adjustments are made.
Set LCD display
XXX
C D R U N
XXX : Item number for which
an adjustment is being executed.
4. In case of CD overall adjustment NG, readjust from the NV
reset (see page 18), The temperature correction (see page 18)
may be omitted.
Set LCD display
000
* * * N G
*** : NG item number.
5. If OK through the CD overall adjustments, then perform MO
overall adjustments.
Set LCD display
000
C D O K
6. Insert MO disc in the set, and press the > key to set the
MO overall adjustment mode. Automatic adjustments are
made.
Set LCD display
XXX
M O R U N
XXX : Item number for which
an adjustment is being executed.
7. In case of MO overall adjustment NG, readjust from the NV
reset (see page 18). The temperature correction (see page 18)
may be omitted.
Set LCD display
000
* * * N G
*** : NG item number.
8. If OK through the MO overall adjustments, press the
• Overall Adjustment error message
The following message will be displayed if adjustment
.
key to set the
procedure is mistaken in the CD and MO overall adjustment.
Message
CLOSE!
Set CD!
Set MO!
NoTmp!
• CD and MO Overall Adjustment Items
1. CD overall adjustment items
Item No.
High reflection electrical offset adjustment
ALFA offset adjustment
HPIT adjustment
key to return to the test mode and terminate the
x/CANCEL
overall adjustment mode.
Set LCD display
000
M O O K
Display timing
During CD/MO/DISC
automatic distinction
overall adjustment
During MO/DISC
automatic distinction
overall adjustment
During offset adjustment
During offset adjustment
During CD/MO/DISC
automatic distinction
overall adjustment
Description
761
VC,VR power supply H/L selection
300
HPIT setting . servo OFF
561
SLED inward movement
562
SLED outward movement
312
Laser ON . Focus UP . vc correction
313
IJ offset adjustment
314
FE offset adjustment
320
Focus servo ON
324
TE offset adjustment 1
321
TE gain adjustment
328
TWPP gain adjustment
324
TE offset adjustment 1
332
TE offset adjustment 2
330
Tracking servo ON
336
ABCD gain adjustment
337
KF gain correction
338
RF gain adjustment
344
FCS gain adjustment
345
TRK gain adjustment
521
Two-axis sensitivity (outer position)
522
Two-axis sensitivity (outer position)
300
HPIT setting . servo OFF
MZ-NF520D
Description
DISC is not inserted.
• CD overall adjustment is not
completed in the MO overall
adjustment.
• CD and MO overall
adjustment is not completed
in the offset adjustment.
MO overall adjustment is not
completed in the offset
adjustment
Temperature correction
(item number 015)
is not finished.