Sony PMC-MD55 Service Manual page 185

Personal minidisc system
Hide thumbs Also See for PMC-MD55:
Table of Contents

Advertisement

• DG BOARD IC601 RU8X12MF-0031 (MD MECHANISM CONTROLLER)
Pin No.
Pin Name
1, 2
DAOUT0, DAOUT1
3 to5
KEY0 to KEY2
6
CHACK-IN
7
PACK-IN
8
PACK-OUT
9, 10
NC
11
AVSS
12
XINT
13
PDOWN
14
NC
15
SQSY
16
DQSY
17 to 19
NC
20
SYS-RST
21
TEST
22
+3.3V
23
VBAT
24
XOUT-T
25
XIN-T
26
GND
27
XOUT
28
XIN
29
EXMEM
30
S1
31
NC
32
SENS
33
SHOCK
34 to 35
NC
36
STB
37
REC P
38
PB P
39
LD-LOW
40
NC
41
MNT2 (XBUSY)
42
MNT3 (SLOCK)
43
LED0
44 to 45
NC
46
RST-LOW
47
GND
I/O
O
Not used (open)
I
Key input terminal (A/D input) Not used (fixed at "H")
Detection input from the disc chucking-in detect switch
I
Not used (fixed at "H")
Detection input from the loading-in detect switch
I
"L" at a load-out position, others: "H" Not used (fixed at "H")
Detection input from the loading-out detect switch (S602)
I
"L" at a load-out position, others: "H"
Not used (fixed at "L")
Ground terminal
I
Interrupt status input from the CXD2654R (IC121)
I
Power down detection signal input terminal "L": power down, normally: "H"
Not used (fixed at "L")
Subcode Q sync (SCOR) input from the CXD2654R (IC121)
I
"L" is input every 13.3 msec Almost all, "H" is input
Digital In U-bit CD format subcode Q sync (SCOR) input from the CXD2654R (IC121)
I
"L" is input every 13.3 msec Almost all, "H" is input
Not used (fixed at "L")
System reset signal input from the reset switch (Q604) "L": reset
I
For several hundreds msec. after the power supply rises, "L" is input, then it changes to "H"
I
Setting terminal for the test mode Not used (fixed at "L")
Power supply terminal (+3.3V)
I
Power supply for the internal real time clock and RAM
O
Sub system clock output terminal (32.768 kHz)
I
Sub system clock input terminal (32.768 kHz)
Ground terminal
O
Main system clock output terminal (12 MHz)
I
Main system clock input terminal (12 MHz)
Setting terminal external ROM mode or internal ROM mode "L": internal ROM mode
I
(fixed at "L")
Not used (open)
Not used (fixed at "L")
I
Internal status (SENSE) input from the CXD2654R (IC121)
I
Track jump detection signal input from the CXD2654R (IC121)
Not used (fixed at "L")
O
Relay drive signal output for the power on/off "L": standby mode, "H": relay on
I
Detection input from the recording position detect switch (S601) "L" active
I
Detection input from the playback position detect switch (S604) "L" active
Loading motor drive voltage control signal output for the loading motor driver (IC602)
O
"H" active
Not used (open)
I
Busy status signal input from the CXD2654R (IC121)
I
Spindle servo lock status monitor signal input from the CXD2654R (IC121)
O
LED drive signal output terminal "L": LED on Not used (open)
Not used (fixed at "L")
Not used (open)
Ground terminal
Description
– 115 –
"L": chucking

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents