This chapter explains how to troubleshoot IES-2500 hardware. Refer also to the Troubleshooting

9.1 The SYS or PWR LED Does Not Turn On

STEP
1
Make sure the power cord is properly connected and the power supply is operating normally. Make sure
you are using the correct power source (refer to the hardware specifications in the appendices).
2
Make sure the main chassis card is properly installed in the main chassis.
3
Make sure the power fuses are not burnt-out. Replace any burnt out fuses. Refer to section 8.1.
4
The LED itself or the unit may be faulty; contact your vendor.

9.2 The ALM LED Is On

The management switch card's ALM (alarm) LED lights when an alarm has been detected on the management
switch card, the IES-2500 fan or the management switch card's INPUT ALARM terminals. Examples of an alarm
on the management switch card are when the management switch card's voltage or temperature is outside of the
normal range.
The ALM (alarm) LEDs on the DSL line cards light when the card is overheated and/or voltage readings are
outside the tolerance levels.
STEP
1
Go to the Hardware Monitor screen in the web configurator to verify the cause of the alarm. See step 2 if
the unit is overheated, step 3 if the problem is with the fans and step 4 if the voltages are out of the
allowed ranges.
2
Ensure that the IES-2500 is installed in a well-ventilated area and that normal operation of the fans is not
inhibited. Keep the bottom, top and all sides clear of obstructions and away from the exhaust of other
equipment.
3
Make sure you can feel and/or hear the fans working - working fans emit a low buzz and blow air. If the
fans are not working properly, refer to the sections on the fan modules for instructions on changing a fuse
or changing the fan module.
4
If the voltage levels are outside the allowed range, take a screen shot of the Hardware Monitor web
configurator screen and contact your vendor.
Hardware Troubleshooting
Hardware Troubleshooting

Table 9-1 SYS LED Troubleshooting

CORRECTIVE ACTION

Table 9-2 ALM LED Troubleshooting

CORRECTIVE ACTION
IES-2500 User's Guide