Specifications - Fujitsu ASYG07LLCC Service Manual

Split type room air conditioner, wall mounted type
Hide thumbs Also See for ASYG07LLCC:
Table of Contents

Advertisement

SPECIFICATIONS

ELECTRICAL DATA
Cool & heat inverter
TYPE
INDOOR UNIT
ASYG07LLCC
OUTDOOR UNIT
AOYG07LLCC
COOLING CAPACITY
2.00 kW
HEATING CAPACITY
2.70 kW
POWER SOURCE
FREQUENCY
Cooling
2.6 A
RUNNING
CURRENT
Heating
3.0 A
Cooling
0.47 kW
INPUT
WATTS
Heating
0.62 kW
EER
Cooling
4.26 kW/kW
COP
Heating
4.35 kW/kW
MOISTURE REMOVAL
1.0 L/h
720 m 3 /h
AIR
Cooling
CIRCULATION
740 m 3 /h
HIGH
Heating
6.0 A
Cooling
MAXIMUM
CURRENT
7.5 A
Heating
2013.10.22
FAN MOTOR
POWER SOURCE
ASYG09LLCC
ASYG12LLCC
INDOOR
AOYG09LLCC
AOYG12LLCC
UNIT
2.50 kW
3.40 kW
Cooling
3.00 kW
4.00 kW
230 V
50 Hz
INDOOR
UNIT
3.5 A
5.2 A
Heating
3.5 A
5.4 A
0.73 kW
1.08 kW
OUTDOOR
UNIT
0.74 kW
1.13 kW
3.42 kW/kW
3.15 kW/kW
NOISE LEVEL
4.05 kW/kW
3.54 kW/kW
1.3 L/h
1.8 L/h
INDOOR
UNIT
720 m 3 /h
Cooling
740 m 3 /h
6.5 A
9.0 A
INDOOR
UNIT
Heating
OUTDOOR
UNIT
230 V
1,320 r.p.m.
High
1,120 r.p.m.
Medium
840 r.p.m.
Low
700 r.p.m.
Quiet
1,360 r.p.m.
High
1,120 r.p.m.
Medium
900 r.p.m.
Low
700 r.p.m.
Quiet
Cooling
730 r.p.m.
860 r.p.m.
Heating
650 r.p.m.
760 r.p.m.
High
43 dB
Medium
38 dB
Low
33 dB
Quiet
22 dB
High
43 dB
Medium
38 dB
Low
33 dB
Quiet
22 dB
Cooling
47 dB
50 dB
Heating
48 dB
51 dB
1
COMPRESSOR AND REFRIGERANT
COMPRESSOR TYPE
DC inverter motor, Rotary
DISCRIMINATION
ASM89D10UFZB
WEIGHT (with oil)
PRECHARGED REFRIGERANT
REFRIGERANT TYPE
Pipe length
15 m
FULL CHARGE
20 m
ADDITIONAL CHARGE
MAXIMUM PIPING HEIGHT
DIMENSIONS
INDOOR UNIT H x W x D
262 x 820 x 206 mm
OUTDOOR UNIT
H x W x D
535 x 663 x 293 mm
WEIGHT
INDOOR UNIT Net / Shipping
OUTDOOR UNIT
Net / Shipping
24 kg / 27 kg
Hermetic type,
4 pole, 3 phase,
ASM98D10UFZA
6.0 kg
8.9 kg
650 g
850 g
R410A
650 g
850 g
750 g
950 g
20 g/m
15 m
7.0 kg / 9.0 kg
26 / 29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asyg12llccAsyg09llccAoyg07llccAoyg09llccAoyg12llcc

Table of Contents