Mantis SwiftSplit 5000 Owner's Manual And Safety Instructions page 17

Mantis log owners manual and safety instructions
Table of Contents

Advertisement

Area
Maintain log splitter with care
• Keep the blade of the log splitter sharp and clean for better and safer performance
• Follow instructions for lubrication and oil change
• Keep proper oil level
• Inspect tool cord periodically and, if damaged, have it replaced by an authorized service facility
• Inspect extension cord periodically and replace, if damaged
• Keep cart dry, clean and free from oil and grease
SKILLED AUTHORIZED PERSONNEL SHOULD PERFORM ANY MAINTENANCE
Maintenance procedure
Nuts, Bolts, hardware
Visually Inspect All Welds.
Check alignment of moving parts and for
damaged or worn parts.
Replace Hydraulic oil
when oil viscosity and force decrease.
You need 0.8-0.9 of a gallon (3-3.3 liters)
of oil to fill up the reservoir
(after old oil is completely drained).
(See section I for instructions)
Recommended Hydraulic oil type:
Mobil DTE11 or equivalent
Do not mix fluid brands and types!
Do not use other grade oils.
IMPORTANT!
OR REPAIR OPERATION NOT DESCRIBED ABOVE.
Inspect /Tighten
Shell Tellus T22
Aral Vitam GF22
SP Energol HCP22
Clean/Lubricate
Machine and cart
Frequency
Before each use
Before each use
After approximately
200 hours of operation
After each use