Sharp LC-70LE740E Service Manual page 89

Hide thumbs Also See for LC-70LE740E:
Table of Contents

Advertisement

LC-60/70LE740E/RU,741E/S,743E,60LE840E/RU,841E/S,843E,80LE645E/RU,646E/S,648E (1st Edition)
4. Basic operation in the Public Mode
Vol (+/-) or Cursor ( / ) Change or execution of the set value.
CH (+/-) or Cursor ( / ) Movement to the selected item.
Decision (ok)
Excution (Used by the items "Execution" and "RESET".)
5. Operation after "RESET"
Select "RESET" in the PUBLIC Mode, and it operates as follows when it is executed (refer to the basic operation).
The set contents in the PUBLIC mode are initialized.
It does not exit the PUBLIC mode.
If "EXCUTE" is not executed, the content that does RESET is not reflected.
6. Setting items. (* Item names and selective items are expressed in English.)
1) Power ON fixed [POWER ON FIXED]
Option
"VARIABLE", "FIXED_ALL", "FIXED_BODYKEY" or "RCRESPOND" (loop enabled)
Default
"VARIABLE"
Function
VARIABLE
FIXED_ALL
FIXED_BODYKEY
RC RESPOND
Key disabled when set
OFF TIMER (SLEEP) (*Only when setting to FIXED_ALL)
other than default
Remarks
When selecting to "FIXED_ALL", function related standby factors (see below) doesn't work. and not selecting.
* These items does not exist according to the model.
If the power button is pressed in the ordinary mode in setting to "FIXED_ALL" and "FIXED_BODYKEY", the caution is displayed for 5 seconds.
When power button on the main unit is pressed
No Power off by power button.
* The OSD display is an example.
If another ODS is previously displayed, the status is reset (MENU or similar).
2) Instantaneous current shutdown setting in turning off the power [SHUT DOWN MODE]
Option
"NORMAL" or "QUICK"
Default
NORMAL
Function
This function decides whether scanning digital tuner is enabled or disabled when the power is standby.
NORMAL
QUICK
: "POWER/RECEPTION" key on TV unit or remote control is enabled.
: "POWER/RECEPTION" key on TV unit or remote control is disabled.
: Only the "MAIN POWER" key on TV unit is disabled (The remote control is enabled).
: The main unit's POWER switch toggles between ON and Standby (the same operation by the
remote control).
OFF TIMER (Sleep)
No operation OFF
No signal OFF (including the power management)
: Scanning digital tuner is enabled when the power is standby.
: Scanning digital tuner is disable.
It is possible to put into the standby state instantaneously due to power off input, when the
power is standby.
Immediately, state is a complete standby.
Public Mode setting screen.
Public Mode
POWER ON FIXED
SHUT DOWN MODE
MAXIMUM VOLUME
VOLUME FIXED
VOLUME FIXED LEVEL
RC BUTTON
PANEL BUTTON
MENU BUTTON
AV POSITION FIXED
ON SCREEN DISPLAY
INPUT MODE START
INPUT MODE FIXED
LOUD SPEAKER
RC PATH THROUGH
232C POWON
PUBLIC MODE
RESET
EXECUTE
When power button on R/C is pressed
No Power off by remote control.
5 – 52
[VARIABLE]
[NORMAL]
[60]
[VARIABLE]
[20]
[RESPOND]
[RESPOND]
[RESPOND]
[VARIABLE]
[YES]
[NORMAL]
[VARIABLE]
[ON]
[OFF]
[DISABLE]
[ON]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents