Operating Instructions; Applications; Before Operation; Working Environment - Hitachi NR 38AK Instruction And Safety Manual

Table of Contents

Advertisement

Available languages

Available languages

English

APPLICATIONS

● Pre-punched holed metal connector to wood
stud installation only.
● Never drive nails into metal or concrete.
○ Metal hardware with pre-punched holes to wood stud
installation only.
Straps, Joist hangers, framing anchors

BEFORE OPERATION

Read section titled "SAFETY" (pages 4 – 7).
Make sure of the followings before operation.

WORKING ENVIRONMENT

● No fl ammable gas, liquid or other fl ammable
objects at worksite.
● Clear the area of children or unauthorized
personnel.

AIR SUPPLY

● NEVER use oxygen or other
● Never
connect
which
potentially
(13.7 bar 14 kgf/cm
● Never use non relieving coupler on Nailer.
1. Power source
○ Use only clean, dry, regulated compressed air as a
power source for this Nailer.
○ Air compressors used to supply compressed air to
this Nailer must comply with the requirements of
the latest version of ANSI Standard B 19.3 "Safety
Standard For Compressors For Process Industries."
10

OPERATING INSTRUCTIONS

DANGER
WARNING
DANGER
bottled gases. Explosion may
occur.
WARNING
Nailer
to
pressure
exceeds
200
).
2
○ Moisture or oil in the air compressor may accelerate
wear and corrosion in the Nailer.
Drain daily.
2. Filter-Regulator-Lubricator
○ Use a regulator with a pressure range of 0 – 120 psi
(0 – 8.3 bar 0 – 8.5 kgf/cm
○ Filter-regulator-lubricator units supply an optimum
condition for the Nailer and extend the Nailer life.
These units should always be used.
Filter ............ The fi lter removes moisture and dirt
mixed in compressed air.
Drain daily unless fi tted with an
automatic drain.
Keep the fi lter clean by regular
maintenance.
Regulator ......The regulator controls the operating
pressure for safe operation of the Nailer.
Inspect the regulator before operation to
be sure it operates properly.
Lubricator .... The lubricator supplies an oil mist to the
Nailer.
Inspect the lubricator before operation
to be sure the supply of lubricant is
adequate.
Use Hitachi pneumatic tool lubricant.
Nailer Side
3. Air hose
Air hose must have a minimum working pressure
rating of 150 psi (10.4 bar 10.6 kgf/cm
psi
of the maximum pressure produced in the system,
whichever is higher.
4. Air consumption
Using the Air consumption table and the Air
compressor size formula, fi nd a correct compressor
size.
).
2
Regulator
Compressor Side
Filter
Lubricator
) or 150%
2

Advertisement

Table of Contents
loading

Table of Contents