When installing: Ensure that the connector is attached firmly.
1150 CRT board assembly (with cable)
For access, remove these FRUs in order:
•
"1010 Battery pack" on page 33
•
"1020 Bottom slot cover" on page 34
•
"1090 Keyboard" on page 41
•
"1110 Keyboard bezel assembly" on page 44
Removal steps of CRT board assembly
Step
Screw (quantity)
3
M2 × 3 mm, wafer-head, nylon-coated (2)
When installing: Ensure that the connector is attached firmly to the system board.
1160 System board assembly and thermal fan assembly
Important notices for handling the system board:
Some components mounted on a system board are very sensitive. Improper handling of a system board can cause
damage to those components, and might cause a system malfunction. When handling the system board, bear the
following in mind:
• The system board has an accelerometer, which can be broken by applying several thousands of G-forces.
Note: Dropping a system board from a height of as little as six inches so that it falls flat on a hard bench can subject
the accelerometer to as much as 6,000 G's of shock.
• Be careful not drop a system board or apply any excessive force to it.
• If a system board is dropped, be sure to document the drop in any reject report, and replace the system board.
3
3
4
1
Torque
Color
Black
0.181 Nm
(1.85 kgf-cm)
.
Chapter 7
Removing or replacing a FRU
49