Appendix A: Alarm I/O Connector - Honeywell 720P User Manual

Ir vari-focal bullet camera
Hide thumbs Also See for 720P:
Table of Contents

Advertisement

9. Appendix A: Alarm I/O Connector

Some features of the Camera can be activated by the external sensor that senses physical
changes in the area Camera is monitoring. These changes can include intrusion detection or
certain physical change in the monitored area. For examples, the external sensor can be a
door switch or an infrared motion detector. These devices are customer provided, and are
available from dealers who carry surveillance and security products. Electrically, they must
be able to provide a momentary contact closure.
This Camera provides wires for general I/O terminal and RS485 interface as below:
Cable for I/O connectors:
Name
Number
Function
12VDC
1
DC 12V (50mA maximum)
DI
2
Digital signal input
GND
3
GND
DO
4
Digital signal output
485+
5
RS485 data +
485-
6
RS485 data -
User can refer to the schematic below to make a proper connection between I/O connector
and external sensor and output device.
Explanation of External I/O Circuit Diagram:
Honeywell
67