CS-PW9GKE / CU-PW9GKE / CS-PW12GKE / CU-PW12GKE
9.2.
INDOOR UNIT
9.2.1.

SELECT THE BEST LOCATION

(Refer to "Select the best location"
section)
9.2.2.
HOW TO FIX INSTALLATION
PLATE
The mounting wall is strong and solid enough to prevent it from
the vibration.
Wall
more than 450mm
Screw
2
165mm
105mm
C
B
More than 450 mm
Wall
S crew
2
224 mm
150 mm
The centre of installation plate should be at more than 450 mm
at right and left of the wall.
The distance from installation plate edge to ceiling should more
than 67 mm.
From installation plate left edge to unit's left side is 62 mm(CS-
UW9GKE) or 98(CS-UW12GKE).
From installation plate right edge to unit's right is 79 mm (CS-
UW12GKE) or 112 (CS-UW12GKE).
:
For left side piping, piping connection for liquid should be
about 10 mm from this line.
:
For left side piping, piping connection for gas should be
about 45 mm from this line.
:
For left side piping, piping connecting cable should be
about 785mm (CS-UW9GKE) or 800mm (CS-UW12GKE)
from this line.
1. Mount the installation plate on the wall with 5 screws or
more.
(If mounting the unit on the concrete wall consider using
anchor bolts.)
Always mount the installation plate horizontally by
aligning the marking-off line with the thread and using a
level gauge.
2. Drill the piping plate hole with ø70 mm hole-core drill.
Line according to the arrows marked on the lower left
and right side of the installation plate. The meeting point
of the extended line is the centre of the hole. Another
method is by putting measuring tape at position as
shown in the diagram above. The hole centre is
obtained by measuring the distance namely 105 mm
and 145mm for left and right hole respectively (CS-
UW9GKE), or 150mm and 125mm for CS-UW12GKE.
Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.
more than 450mm
Installation
( E )
225mm
plate
1
A
145mm
B
(For Models:CS-PW9GKE)
More than 450 mm
( B )
A
Ins tallation
125 mm
plate
1
Meas uring tape
(For Models:CS-PW12GKE)
9.2.3.
TO DRILL A HOLE IN THE WALL
AND INSTALL A SLEEVE OF
PIPING
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the wall.
Wall
Caution
When the wall is hollow, please be sure to use the
sleeve for tube ass•y to prevent dangers caused by
mice biting the connecting cable.
4. Finish by sealing the sleeve with putty or caulking
compound at the final stage.
Wall
219 mm
9.2.4.

INDOOR UNIT INSTALLATION

1. For the right rear piping
2. For the right and right bottom piping