31
The registration roller fails to rotate.
Cause
Step
Registration
1
roller
DC controller
2
PCB
Registration
clutch (CL1)
32
The scanner fails to move forward/in reverse.
Cause
Step
Scanner drive
1
cable
Scanner path
2
(foreign matter)
Connector
3
(poor contact)
Scanner motor
4
(M2)
DC controller
PCB
Checks
Press the Copy Start key. Does
the registration roller rotate
immediately after the scanner
moves forward?
Does the voltage between the
connector J114-B10 (+) and
the connector J114-B1 (–) on
the DC controller PCB change
from 0 V to 24 V immediately
after the scanner starts to
move forward?
Checks
Is the scanner drive cable rout-
ed correctly?
Is the scanner rail free of dirt,
and does the scanner move
smoothly?
Check the wiring/connection
from the connector J116 on the
DC controller PCB to the scan-
ner motor. Is it normal?
Replace the scanner motor. Is
the problem corrected?
TROUBLESHOOTING MALFUNCTIONS
Yes/No
YES
Check the registration roller
drive assembly.
NO
Replace the DC controller
PCB.
YES
Check the wiring from the DC
controller PCB; if normal,
replace CL1.
Yes/No
NO
Re-route it.
NO
Check the surface of the scan-
ner rail for foreign matter or an
object that comes into contact
with the scanner.
NO
Correct it.
YES
End.
NO
Replace the DC controller
PCB.
Action
Action