PBUS Accessories

Six accessories (keypads, proximity readers, remote receivers) can be
connected to the AE-2000's three PBUS input/output ports. A typical
application for a remote keypad would be to control a second door or
gate.
Linear's PBUS devices compatible with the AE-2000 are:
• AM-RRR Remote Radio Receiver
• AM-RPR Radio Proximity Receiver
• AM-KP Exterior Keypad
• AM-KPI Interior Keypad
• AM-CRI Card Reader Interface
1. Mount and install the accessory as described in its installation
instructions.
2. Route 6-conductor cable from the AE-2000 to the accessory.
For wire runs up to 300 feet use 24 AWG Belden Type 9931 or
equivalent.
For wire runs up to 600 feet use 20 AWG Weico Type 9405 or
equivalent.
3. Set the DEVICE ADDRESS rotary switch in the accessory to
a unique address number. When programming the system, the
device address number will identify each PBUS accessory to the
AE-2000.
4. Connect the 6-conductor cable to the accessory and the AE-2000.

Wiegand Accessories

The two AE-2000 Wiegand inputs (WIEGAND A & B) can connect to
a large variety of 26, 30, and 31-bit Wiegand output accessories. The
Wiegand format is a common standard for access control equipment.
A typical application would be to add swipe card or proximity readers to
the system.
✦ NOTE: Depending on the Wiegand accessory used, the LED1,
LED2, and HOLD connections may not be required.
LED1 output is switched to ground during non-access time.
LED2 output is switched to ground for one second during access
time.
1. Mount and install the Wiegand accessory as described in its
installation instructions.
2. Route a cable from the AE-2000 to the accessory.
For wire runs up to 300 feet use 24 AWG Belden Type 9931 or
equivalent.
For wire runs up to 500 feet use 20 AWG Weico Type 9405 or
equivalent.
3. Connect the cable to the accessory and the AE-2000 as shown in
the fi gure.
14
NOTE: UP TO SIX PBUS
DEVICES MAY BE CONNECTED
TO THE THREE SETS OF AE-2000
PBUS TERMINALS
PWR
GND
REMOTE
DAT1
PBUS
DAT0
DEVICE
DVAL
PCLK
SET THE REMOTE
DEVICE ADDRESS
SWITCH TO A UNIQUE
DEVICE ADDRESS
LED2
HOLD
LED1
REMOTE
DAT1
WIEGAND
DEVICE
DAT0
GND
PWR
NOTE: THE LED1, LED2, AND HOLD
CONNECTIONS MAY NOT BE REQUIRED
DEPENDING ON THE WIEGAND DEVICE USED
PBUS
TERMINALS
PWR
GND
DAT1
DAT0
DVAL
PCLK
WIEGAND
TERMINALS
LED2
HOLD
LED1
DAT1
DAT0
GND
PWR

Hide quick links: