Desa (V)T32N-A series Owner's Operation And Installation Manual page 11

Direct-vent
Table of Contents

Advertisement

Minimum Pipe
Overlap 1
/
"
1
4
Wall
Firestop
Direct Vent
Pipe
Maintain 1"
Minimum Air Space
Around Outer Pipe
When Penetrating
a Wall
11
/
" x 11
1
2
Framed Opening
Figure 13 - Typical Horizontal
Termination Cap Mounting with
Additional Siding Standoff Installed
Horizontal Termination Configurations
Figures 14 through 18 show different configura-
tions and alternatives for venting with horizontal
termination. Each figure includes a chart with
critical minimum and maximum dimensions
which MUST be met. IMPORTANT: If using a
venting configuration of only horizontal venting
with no vertical run, a 1/4" rise for every 12" of
run toward termination is required.
NOTICE: Do not seal termination
cap to vent pipe. Cap must be
removable for vent inspection
and maintenance.
WARNING: Never run vent
downward as this may cause
excessive temperatures which
could cause a fire. Operation of
improperly installed and main-
tained venting system could
result in serious injury, property
damage or loss of life.
116646-01H
VENTING INSTallaTION
Siding
Standoff
Screws
High Wind
Termination
Apply Mastic
to Outside
Edge of
Standoff
/
"
1
2
Exterior Wall
with Vinyl Siding
www.desatech.com
Continued
GROUND FLOOR INSTALLATION
Recommended Applications:
• Installation using cabinet surrounds
• Through the wall using round or square
termination (up to 12") adjustable pipe)
• NOT FOR CORNER INSTALLATION
Horizontal High
Wind Square
Termination
Wall
Firestop
45° Elbow
Wall
Firestop
Figure 14 - Horizontal Termination
Configuration for Square or Round
45° Elbow
Adjustable
Pipe 12"
Max.
Square Termination
Vertical (V)
Horizontal (H)
29
/
"
3
4
Exterior
Portion of Wall
Firestop (Round
Termination Only)
Slide Ring
Over Elbow
to Complete
Connection
Horizontal Round
Termination
Round Termination
(Kit HTK Shown)
Termination
17" max.
11