TROUBLESHOOTING GUIDE
PROBLEMS
(SYMPTOMS)
The pilot arc is normal, but the arc
will not transfer to the workpiece.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-888-935-3877.
TROUBLESHOOTING & REPAIR
POSSIBLE AREAS OF
MISADJUSTMENT(S)
CUTTING PROBLEMS
1. Make sure the operating proce-
dure is correct for the process.
See the Operation section of
this manual.
2. Make sure the work clamp is
connected tightly to the work-
piece.
3. The workpiece must be electri-
cally conductive material.
CAUTION
PRO-CUT 55
Observe Safety Guidelines
detailed in the beginning of this manual.
RECOMMENDED
COURSE OF ACTION
1. Check the lead connections X2,
X4 and B21 at the output board.
2. Check
the
output
potentiometer (R1).
resistance is 10 ohms.
check the associated leads for
loose or faulty connections to
the display board.
Wiring Diagram.
3. Check leads #216, #218 and
#219 between the display
board and the control board.
Check for loose or faulty con-
nections.
See the Wiring
Diagram.
4. The control board may be
faulty. Replace.
5. The output board may be faulty.
Perform the Output Board
Resistance Test.
6. The display board may be
faulty. Replace.
F-7