Connecting Transceivers To A Copper Network; Verifying The Installation; Verifying Newly Installed Modules; Example: Show Module Command Output For C6800-48P-Tx-Xl - Cisco Catalyst 6800 Installation Manual

Ethernet module
Table of Contents

Advertisement

Connecting Transceivers to a Copper Network

Connecting Transceivers to a Copper Network
To comply with GR-1089 intrabuilding lightning immunity requirements, you must use grounded, shielded,
Caution
twisted-pair Category 5 cabling.
Step 1
Insert the network cable RJ-45 connector into the RJ-45 connector on the transceiver.
When connecting to a 1000BASE-T-compatible switch or repeater, use four-twisted-pair, crossover Category 5 cabling.
Step 2
Insert the other end of the network cable into an RJ-45 connector on a 1000BASE-T-compatible target device.

Verifying the Installation

Verifying Newly Installed Modules

Enter the show module or show port [modnum/port_num] privileged EXEC command.
This verifies that the system acknowledges the new modules and has brought them online.
What to Do Next
Enter the ping host user EXEC command to ping a host and check connectivity.
If the host is unresponsive, check the IP address of the switch and default IP route, if appropriate.

Example: show module Command Output for C6800-48P-TX-XL

These are examples of the show module command output for the C6800-48P-TX-XL Ethernet module:
Switch# show module sw 1
Switch Number:
----------------------
Mod Ports Card Type
--- ----- -------------------------------------- ------------------ -----------
1
2
3
4
5
6
Mod MAC addresses
--- ---------------------------------- ------ ------------ ------------ -------
1
2
3
4
5
6
Catalyst 6800 Ethernet Module Installation Guide
34
1
Role:
-----------------------------
20
DCEF2T 4 port 40GE / 16 port 10GE
4
WiSM 2 WLAN Service Module
5
Supervisor Engine 2T 10GE w/ CTS (CSSO VS-SUP2T-10G
5
Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G
4
Network Analysis Module 3
48
DCEF-XL 48P 10/100/1000MB Ethernet
1cdf.0f9b.df26 to 1cdf.0f9b.df39
e05f.b994.2660 to e05f.b994.266f
2c54.2dc4.a0a5 to 2c54.2dc4.a0ac
2c54.2dc3.7499 to 2c54.2dc3.74a0
1cdf.0f9b.a76e to 1cdf.0f9b.a77d
7c69.f69b.c8d8 to 7c69.f69b.c907
Installing and Removing Modules, Transceivers, and Attaching Cables
Virtual Switch Standby
Model
WS-X6904-40G
WS-SVC-WISM2-K9
WS-SVC-NAM-3-K9
C6800-48P-TX-XL
Hw
Fw
1.0
12.2(50r)SYL 15.1(2)SY2
1.0
12.2(18r)S1
1.5
12.2(50r)SYS 15.1(2)SY2
1.5
12.2(50r)SYS 15.1(2)SY2
1.1
12.2(50r)SYL 15.1(2)SY2
0.1
12.2(18r)S1
Serial No.
SAL1624E826
SAL1523FLRV
SAL17152F6Q
SAL17152F7C
SAL16127XFD
SAL1736CC7W
Sw
Status
Ok
15.1(2)SY2
Ok
Ok
Ok
Ok
15.1(2)SY2
Ok

Advertisement

Table of Contents
loading

Table of Contents