Vanguard VYD18NRB Owner's Operation page 4

Table of Contents

Advertisement

1. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases.
2. Do not place propane/LP supply tank(s)
inside any structure. Locate propane/LP
supply tank(s) outdoors (propane/LP units
only).
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not
use any phone in your building
• immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions
• if you cannot reach your gas supplier,
call the fire department
4. This heater shall not be installed in a bed-
room or bathroom, unless installed as a
vented appliance. See Installing Damper
Clamp Accessory for Vented Operation,
page 12. This gas log set may not be
installed as a vented appliance in a bed-
room or bathroom in the Commonwealth
of Massachusetts.
5. Before installing in a solid fuel burning fire-
place, the chimney flue and firebox must
be cleaned of soot, creosote, ashes and
loose paint by a qualified chimney cleaner.
Creosote will ignite if highly heated. A dirty
chimney flue may create and distribute
soot within the house. Inspect chimney
flue for damage. If damaged, repair flue
and firebox before operating heater.
6. Do not burn solid-fuel in a masonry or
UL127 factory-built fireplace in which a
vent-free room heater is installed.
7. If fireplace has glass doors, never operate
this heater with glass doors closed. If you
operate heater with doors closed, heat
buildup inside fireplace will cause glass to
burst. Make sure there are no obstructions
across openings of fireplace.
8. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
page 24.
4
SAFETY
Continued
9. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls and furniture.
10. This heater needs fresh, outside air venti-
lation to run properly. This heater has an
Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS shuts down the
heater if enough fresh air is not available.
See Air for Combustion and Ventilation,
page 6. If heater keeps shutting off, see
Troubleshooting, page 26.
11. Do not run heater
• where flammable liquids or vapors are
• under dusty conditions
12. Do not use this heater to cook food or burn
paper or other objects.
13. Do not use heater if any part has been ex-
posed to or under water. Immediately call
a qualified service technician to inspect
the room heater and to replace any part
of the control system and any gas control
which has been under water.
14. Do not operate heater if any log is broken.
Do not operate heater if a log is chipped
(dime-sized or larger).
15. Turn heater off and let cool before ser-
vicing, installing or repairing. Make sure
the selector switch is in the OFF position
(Remote-Ready Models Only). Only a
qualified service person should install,
service or repair heater.
16. Make sure the selector switch is in the
OFF position when you are away from
home for long periods of time (Remote-
Ready Models Only).
17. Operating heater above elevations of
4,500 feet may cause pilot outage.
18. To prevent performance problems, do not
use propane/LP fuel tank of less than 100
lb. capacity (propane/LP units only).
19. Provide adequate clearances around air
openings.
www.fmiproducts.com
used or stored
113093-01J

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents