Carrier 58MXA Installation, Start-Up, And Operating Instructions Manual page 27

Deluxe 4–way multipoise fixed-capacity direct vent condensing gas furnace
Table of Contents

Advertisement

ALTITUDE (FT)
UNIT SIZE
040-08
040-12
060-08
060-12
060-16
080-12
080-16
080-20
0 to 2000
100-16
100-20
120-20
140-20
ALTITUDE (FT)
UNIT SIZE
040-08
040-12
060-08
060-12
060-16
080-12
080-16
080-20
2001 to 3000
100-16
100-20
120-20
140-20
ALTITUDE (FT)
UNIT SIZE
040-08
040-12
060-08
060-12
060-16
080-12
080-16
080-20
3001 to 4000
100-16
100-20
120-20
140-20
See notes at end of table
37.) Sidewall termination may require sealing or shielding of
building surfaces with a corrosive resistance material due to
corrosive combustion products of vent system.
Table 7—Maximum Allowable Pipe Length (ft)
TERMINATION
PIPE DIA
TYPE
(IN.)*
1
2 Pipe or 2-in
1-1/2
Concentric
2
1-1/2
2 Pipe or 2-in
Concentric
2
1-1/2
2 Pipe or 2-in
2
Concentric
2-1/2
2
2 Pipe or 3-in
2-1/2
Concentric
3
2-1/2 one disk
2 Pipe or 3-in.
3†
Concentric
3† no disk
2-1/2 one disk
3† one disk
2 Pipe or 3-in.
Concentric
3† no disk
4† no disk
TERMINATION
PIPE DIA
TYPE
(IN.)*
1-1/2
2 Pipe or 2-in
Concentric
2
1–1/2
2 Pipe or 2-in
Concentric
2
2
2 Pipe or 2-in
Concentric
2-1/2
2–1/2
2 Pipe or 3-in
Concentric
3
3
2 Pipe or 3-in.
3† no disk
Concentric
4† no disk
3† one disk
2 Pipe or 3-in.
3† no disk
Concentric
4† no disk
TERMINATION
PIPE DIA
TYPE
(IN.)*
1-1/2
2 Pipe or 2-in
Concentric
2
1–1/2
2 Pipe or 2-in
Concentric
2
2
2 Pipe or 2-in
Concentric
2-1/2
2-1/2
2 Pipe or 3-in
Concentric
3
3† no disk
2 Pipe or 3-in.
Concentric
4† no disk
3† one disk
2 Pipe or 3-in.
3† no disk
Concentric
4† no disk
27
NUMBER OF 90° ELBOWS
1
2
3
5
NA
NA
70
70
65
70
70
70
20
15
10
70
70
70
10
NA
NA
55
50
35
70
70
70
5
NA
NA
40
30
20
70
70
70
10
NA
NA
45
40
35
70
70
70
5
NA
NA
40
35
30
60
56
52
70
70
70
NUMBER OF 90° ELBOWS
1
2
3
67
62
57
70
70
70
17
12
7
70
67
66
49
44
30
70
70
70
35
26
16
70
70
70
14
9
NA
70
70
63
70
70
70
20
15
10
39
35
31
70
70
70
NUMBER OF 90° ELBOWS
1
2
3
64
59
54
70
70
70
16
11
6
68
63
62
46
41
28
70
70
70
33
24
15
70
70
70
65
58
51
70
70
70
11
6
NA
30
26
22
70
70
70
Extended Exposed Sidewall Pipes
Sidewall combustion-air and vent pipe terminations may be
extended beyond area shown in Fig. 39 or 40 in outside ambient by
insulating pipes as indicated in Table 8.
4
5
6
NA
NA
NA
60
60
55
70
70
70
5
NA
NA
70
70
70
NA
NA
NA
30
30
20
70
70
70
NA
NA
NA
20
10
NA
70
70
70
NA
NA
NA
30
25
20
70
70
70
NA
NA
NA
25
20
15
48
44
40
70
70
70
4
5
6
52
52
47
70
70
70
NA
NA
NA
61
61
61
25
25
15
70
70
70
16
6
NA
70
66
61
NA
NA
NA
56
50
43
70
70
70
5
NA
NA
27
23
19
70
70
70
4
5
6
49
48
43
70
70
70
NA
NA
NA
57
57
56
23
22
13
70
70
70
14
5
NA
66
61
56
44
38
31
70
70
70
NA
NA
NA
18
14
10
70
70
70