Ringing Of Compulsory Operation, Compulsory Frost Removal Buzzer; Defrost Function; Refrigerator Lamp Automatically Off - LG LSC26905TT Service Manual

Hide thumbs Also See for LSC26905TT:
Table of Contents

Advertisement

MICOM FUNCTION

2-12. Ringing of compulsory operation, compulsory frost removal buzzer

1. If pressing the test button in the Main PCB, a beep will sound.
2. In selecting compulsory operation, alarm sound is repeated and completed in the cycle of On for 2/10 second and Off for
1 8/10 second three times.
3. In selecting compulsory frost removal, alarm sound is repeated and completed in the cycle of On for 2/10 second , Off for
2/10 second, On for 2/10 second and Off for 1 4/10 second three times.

2-13. Defrost function

1. Defrost is performed whenever total operation time of compressor becomes 7 ~ 7 1/2 hour.
2. In providing initial power (or returning power failure), frost removal starts whenever total operation time of compressor
becomes 4 ~ 4 1/2 hour.
3. Defrost is completed if temperature of a defrost sensor becomes more than 5°C after starting defrost. The defrost cycle
will fail if there frigerator does not reach a temperature of 5°C (9 °F)two hours into the defrost cycle.
4. The defrost cycle will not operate of the defrost sensor fails, arcs, or shorts out.

2-14. Refrigerator lamp automatically off

• Refrigerator lamp turns on and off by refrigerator door switch.
• If refrigerator lamp continuously turns on more than 7 minutes, the refrigerator room lamp turns off automatically period.
- 24 -