E-5
PROBLEMS
(SYMPTOMS)
Pilot arc starts but will not transfer
when brought near work.
Pilot arc initiates but turns off before
transferring to work. Cutting arc
appears to turn off while cutting.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
1. Check work lead connection for
clean, secure connection.
2. Plasma will only cut conductive
material. Do not attempt to cut
fiberglass, plastic, rubber, PVC or
any other non-conductive material.
3. Make sure work piece is clean
and dry. Remove any scale, rust
or dross.
4. Possible faulty Inverter board.
5. Check all connections to Control
Board.
1. Input voltage is below 208V.
2. Air pressure is set too high.
TOMAHAWK™ 625
CAUSE
If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.
Lower air pressure by turning regula-
tor knob. Pressure may require
being set lower than blue arrow indi-
cator.
CAUTION
RECOMMENDED
COURSE OF ACTION