Installation; Technical Specifications - Lincoln Electric RED-D-ARC PM 255 Operator's Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

A-1
TECHNICAL SPECIFICATIONS – PM 255
Standard Voltage/Frequency
230/460/575/60 Hz
Duty Cycle
40%
60%
100%
Welding Current Range (Continuous) Maximum Open Circuit Voltage
30 – 300 Amps
Input Voltage/
Fuse or Breaker
Frequency (Hz)
Size (Super Lag)
230/60
460/60
575/60
Height
31.79 in
808 mm
Wire Speed

INSTALLATION

INPUT – SINGLE PHASE ONLY
Input Current @ 200 Amp Rated Output Input Current @ 250 Amp Rated Output
RATED OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
Input Ampere
Rating On
Nameplate
60
30
25
NOTE: Use #10 AWG Grounding Wire
PHYSICAL DIMENSIONS
Width
18.88 in
480 mm
WIRE SPEED RANGE
41/20/16 Amps
Amps
250 Amps
200 Amps
145 Amps
OUTPUT
40 Volts
75°C Copper Wire
in Conduit
AWG (IEC) Sizes
(For lengths
up to 100 ft.)
46
10 (6 mm
24
14 (2.5 mm
19
14 (2.5 mm
Depth
38.78 in
985 mm
50 – 700 IPM (1.27 – 17.8 m/minute)
PM 255
50/24/19
Volts at Rated Amperes
26 Volts
28 Volts
26 Volts
Welding Voltage Range
10-28 Volts
75°C Copper Wire
in Conduit
AWG (IEC) Sizes
(For lengths
exceeding 100 ft.)
2
)
8 (10 mm
2
2
)
12 (4 mm
2
2
)
12 (4 mm
Weight
220 Ibs
100 kg
A-1
2
)
)
)

Advertisement

Table of Contents