E-3
PROBLEMS
(SYMPTOMS)
C. Engine will not go to high idle
when attempting to weld.
D. Engine will not go to high idle
when using auxiliary power.
E.
Engine will not crank or is
hard to crank.
F.
Engine shuts down.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
1.
Poor work lead connection to
work.
2.
No voltage signal from the
current sensor.
3.
No open circuit voltage on
output studs.
4.
Faulty P.C. Board.
5.
Insufficient voltage present between
terminals #253 and #5G (Volatge
should be 12 V DC)
6.
Faulty wiring in solenoid circuit.
1.
No voltage signal from the
current sensor.
2.
Auxiliary power load less than
100 to 150 watts.
3.
Faulty P.C. Board
4.
Insufficient voltage present between
terminals #253 and #5G (Volatge
should be 12 V DC)
5.
Faulty wiring in solenoid circuit.
1.
Battery will not hold a charge.
Faulty Battery.
2.
No or insufficient charging
current.
3.
Loose battery cable
connection(s).
1.
Out of fuel.
RANGER 8+ DIESEL
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
1.
2.
3.
1.
CAUTION
RECOMMENDED
COURSE OF ACTION
Make certain work clamp is tightly
connected to clean base metal.
Check for disconnected or broken
leads in idler sensing circuit.
Check generator output.
Replace P.C. Board with
known good one.
Check for proper connection of
leads.
Check for broken or loose leads
#5G and #253.
Check for disconnected or broken
leads in idler sensing circuit.
Idler may not function with less
than 100 to 150 watt load. Set
idler switch to high idle.
Replace P.C. Board with known
good one.
Check for proper connection of
leads.
Check for broken or loose leads
#5G and #253.
Replace with known good one.
Check the connection of the
lead from the voltage regulator
on the engine to the charging
ammeter and the battery.
Check and tighten connection
at battery, at starter, at engine
foot, or at frame.
Add fuel.
E-3

Advertisement