D-1

MAINTENANCE

ELECTRIC SHOCK can kill.
• Only Qualified personnel should
perform this maintenance.
• Turn the input power OFF at the
disconnect switch or fuse box
before working on this equipment.
Do not touch electrically hot parts.
Routine maintenance consists of periodically blowing
out the machine, using a low pressure airstream, to
remove accumulated dust and dirt from the intake and
outlet louvers, and the cooling channels in the
machine.
Calibration of the Power Wave 455M is critical to its
operation. Generally speaking the calibration will not
need adjustment. However, neglected or improperly
calibrated machines may not yield satisfactory weld
performance. To ensure optimal performance, the cali-
bration of output Voltage and Current should be
checked yearly.
Output Voltage and Current are calibrated at the facto-
ry. Generally speaking the machine calibration will not
need adjustment. However, if the weld performance
changes, or the yearly calibration check reveals a
problem, contact the Lincoln Electric Company for the
calibration software utility.
The calibration procedure itself requires the use of a
grid, and certified actual meters for voltage and cur-
rent. The accuracy of the calibration will be directly
affected by the accuracy of the measuring equipment
you use. Detailed instructions are available with the
utility.
POWER WAVE 455M
D-1