Technical data
Flow rates / Inlet volume
Flow meter (at 0,3 bar
= quantity 1,1 l/min)
Spray pump
Drain pump
Pump height max.
Inlet valve
Valve for Zone washing
Valve for sieve
Spray arm lower
Sprayarm upper
Ceiling rotor
Water distribution
Fine sieve
Self cleaning
micro filter
Electrical data
Base data
Voltage
Frequency
Total power
Fuse
Motor
Spray pump motor
Voltage
Power consumption
HI
HA
Capacitor
Drain pump motor
Voltage
Resistance
Heating
1 Element system
Voltage
Power consumption
Resistance
Heating speed
Temperature on surface
Double safety thermostat
self reset
Whirlpool Europe
Customer Service
208
lmp/l
~ 70
l/min
16
l/min
1,3
m
4,5
l/min
30
l/min
8
l/min
33
l/min
30
l/min
8
l/min
100
%
~ 32
%
220/230
V
50
Hz
2,0-2,2
kW
10
A
220/230
V
~190
W
69
36,2
4
F
220/240
V
146
220/230
V
1,8/2,0
kW
12,5-13,5 Ω
~ 2,5
˚C/min
~ 115
˚C
85
˚C
Potentiometer
Position 0
Position 1
Position 2
Position 3
Position 4
Position 5
Position 6
Water valves
Single valve at inlet hose
Voltage
Frequency
Resistance
Regenerating valve
Voltage
Frequency
Resistance
Valve for zone washing
Voltage
Frequency
Resistance
Valve for sieve
Voltage
Frequency
Resistance
Coil of dispenser
Voltage
Frequency
Resistance
Relay
Heating relay
Voltage
Frequency
Resistance
22.02.1996 / Page 3
Doc. No: 4812 718 11648
2,0
kΩ
4,3
kΩ
9,0
kΩ
13,3
kΩ
17 ,5
kΩ
22,2
kΩ
24,2
kΩ
220/240
V
50/60
Hz
2,06
kΩ
220/240
V
50/60
Hz
3,13
kΩ
220-240
V
50/60
Hz
3,71
kΩ
220/240
V
50/60
Hz
3,83
kΩ
220/240
V
50/60
Hz
1,43
kΩ
220/240
V
50/60
Hz
5,5
kΩ

Hide quick links: