11. TABLE OF ERROR CODES

11. TABLE OF ERROR CODES
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet
before opening the cover of the control box. Touching areas where high voltages are present can result in severe
injury.
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display
window. Follow the remedy procedure to eliminate the cause of the problem.
Switch-related errors
Code
Stop switch was pressed. Press the RESET key to clear the error.
E010
Stop switch was pressed. Press the RESET key to clear the error.
E011
Press the
The stop switch was still being pressed, or there is a problem with the stop switch connection.
E015
Turn off the power, and then check that connector P13 on the main P.C. board is properly connected.
Foot switch is depressed to the 2nd step. (If using a two-pedal foot switch, the power was turned on while the
start switch was still depressed, or the start switch was pressed without the work clamp being lowered.)
E025
Turn off the power and check the foot switch.
Foot switch is depressed to the 1st step. (Work clamp switch if using a two-pedal foot switch)
E035
Turn off the power and check the foot switch.
A foot switch that does not match specifications is connected, or work clamp mode has not been set correctly.
E036
Use a foot switch that matches specifications, or initialize the memory switch settings.
Machine head tilting was detected after the power was turned on.
Turn off the power, and then return the machine head to its original position.
E050
Check that connector P9 on the main P.C. board is properly connected.
Machine head tilting was detected while the sewing machine was operating.
E051
Turn off the power, and then check that connector P9 on the main P.C. board is properly connected.
Machine head tilting was detected when the power was turned on.
Turn off the power, and then return the machine head to its original position.
E055
Check that connector P9 on the main P.C. board is properly connected.
An operation panel key was still being pressed when the power was turned on, or key is faulty.
E065
Turn off the power and check the operation panel.
Upper shaft motor-related errors
Code
Needle up stop position error.
E110
Turn the machine pulley until the point where the error display disappears.
Upper shaft did not stop at the needle up stop position when the sewing machine stopped.
E111
Turn the machine pulley until the point where the error display disappears.
Thread trimming was not completed.
E121
Turn off the power, and then check if the cutting edges of the fixed knife and movable knife are damaged or worn.
Sewing machine motor stopped due to a problem, or synchronizer is faulty.
Turn off the power, and then turn the machine pulley and check if the sewing machine has locked up.
E130
Check that connectors P4 and P5 on the power supply motor P.C. board are properly connected.
Synchronizer is faulty.
Turn off the power, and then check that connector P5 on the power supply motor P. C. board is properly
E131
connected.
64
key to move the feed mechanism so that you can continue sewing.