4. SPECIFICATIONS OF ELECTRICAL PARTS

Parts name
Compressor
Fan motor
Running capacitors
Relay
Float switch
Transformer
Microcomputer
Room temperature sensor
(Ta-sensor)
Heat-exchanger sensor
(Tc-sensor)
Power supply cord with plug
Fuse

3. APPEARANCE

Fig. 3-1
Type
Single phase, 50 Hz, 220/230/240V ~, AC. 750W output
PH94X1-4G1
Winding resistance
(Ω) (at 20°C)
Single phase, 50 Hz, 230V, AC. 20W output
STF-230-20-4C
Winding resistance
(Ω) (at 20°C)
EARU40M206UF
400V, 20µF (for compressor)
EEP2H105HWNB05
500V, 1µF (for fan motor)
AJE6412
250V, 3A (for fan motor)
PC12D2
250V, 15A (for compressor)
FS-085-002F
Rated current, 0.1A 100V DC
FT67-2
Primary 220V ~ 240V, Secondary 12.3V ~ 13.6V
TMP47C440AN
(Microcomputer)
Differential ±2°C, Adjustable range 17 ~ 28°C
(Microcomputer)
Differential ±2°C
Copper wire minimum 1.0 mm
TSCR
6.3A
– 4 –
Specifications
Red-Black
White-Black
4.55
8.55
Orange-Blue
Red-Black
Black-Orange
205.0
145.9
111.1
2
Red-White
13.1
Black-Orange
102.5