13-1.Condenser Servicing Procedures

(1) Pull out the air filter.
(2) Remove six screws at the back and take off the
rear panel. Also, pull out the drain hose from
case of hose.
Fig. 13-1
(3) Open the front door and remove the tank.
(4) Remove the inner cover (screwed down at five
spots).
Inner cover
Fig. 13-2

13. CLEANING METHOD OF CONDENSER

Tank
(5) Remove two screws fastening the condenser
cover (one in the front part and another in the
rear).
(6) Remove the condenser cover by pulling it ob-
liquely upward, then the condenser will be ex-
posed.
(7) When assembling, follow the reverse procedures.
– 26 –
Condenser cover
Fig. 13-3
Condenser cover
Fig. 13-4