Broan B5330SS Installation Instructions Manual page 7

Chimney range hood
Table of Contents

Advertisement

Available languages

Available languages

6" ROUND
STEEL DUCT
DUCT LENGTH
DECORATIVE
FLUE
8. Measure and install steel ductwork to hood duct connector.
Use duct tape to make all joints secure and air tight.
9. Hold hood up close to wall mounting location and plug
power cord into wall outlet.
10. Align the hood and center it above the hood mounting
bracket. Make sure ductwork on hood lines up and attaches
to ductwork in ceiling. Gently lower the hood until it securely
engages the bracket.
11. Use duct tape to make all joints secure and air tight.
INSIDE BACK OF HOOD
SIDE VIEW
HOLE LOCATIONS
12. With the hood hanging in place, drill through both holes
located in the inside lower back of hood using a 5 ⁄ 1 6" drill bit.
Insert the included drywall anchors into the drilled holes (one
for each hole). Install (2) washers and (2) #8 x 1-3/16" pan
head mounting screws through the hood back and into the
drywall anchors. Verify that the hood is centered and leveled.
Tighten all screws completely.
13. Reinstall grease filters by aligning rear filter tabs with slots
in the hood. Push back the metal latch tab, push filter into
position and release. Make sure filters are securely engaged
after installation.
14. Slide the upper flue upward until it is aligned with its mounting
15. Remove any protective plastic remaining on hood.
INSTALL THE HOOD
(Non-Ducted Hoods Only)
MOTOR/
BLOWER
ASSEMBLY
Ø 5/16" TYP.
NOTE: Non-ducted installations require Non-Duct Kit,
Model RK56 (purchase separately).
1. CAUTION: Do not use plastic or rigid metal duct.
2. Do not remove the protective plastic film covering the
3. Lay the back side of the hood flat on a table. Use a piece of
4. Attach damper / duct connector to top of hood using (4) #8
5. Remove damper flaps from damper / duct connector and
MODELS B5330SS • B5336SS
UPPER FLUE MOUNTING BRACKET
UPPER
FLUE
bracket. The bracket should be inside the flue. Secure the
upper flue to the upper flue mounting bracket using (2) #8 x
3/8" mounting screws.
NON-DUCT KIT MODEL RK56 CONTENTS
RECIRCULATION
NON-DUCT
8 MOUNTING
PLENUM
SCREWS
(ST4 x 8
Round Head)
NON-DUCT PLENUM
COLLAR
2 TIE
WRAPS
decorative flue and the hood at this time.
cardboard to avoid damaging the table or the hood.
x 3/8" Pan Head mounting screws.
discard flaps.
Page 7
NON-DUCTED
FILTERS
FLEXIBLE DUCT

Advertisement

Table of Contents
loading

This manual is also suitable for:

B5336ss

Table of Contents