7.0
Reliability
7.1
Mean Time Between Failures
MTBF to be calculated according to military standard MIL-HDBK-
217C.
MTBF (Excluding the CRT) > 60,000 hrs @ 70% CL before FCS
MTBF (Excluding the CRT) > 120,000 hrs @ 90% CL after FCS
Practice of MTBF =
8.0
Quality assurance requirements
8.1
Acceptance test
according to MIL-STD-105D
AQL : 0.65 (major)
Customer acceptance criteria : UAW0377/00
9.0
The serviceability of this monitor should fulfill the
TYPE
OEM
2003-12-19
C.C.Liao
GENERAL PRODUCT SPECIFICATION(Continued)
Total hrs (power on) x Total sets
----------------------------------------
2.50 (minor)
(please also refer to annual quality agreement)
Serviceability
requirements which are prescribed in UAW-0346 and must
Be checked with the check list UAT-0361.
22" CMTR-M25P-Dell-P1230
: 6L3P10/76
: Dell P1230 130KHz
2003-12-19
NO. of failed sets
Control II level
8639 000 15121
590
22