Kenwood KDC-W4044UA Service Manual page 7

Cd receiver
Table of Contents

Advertisement

MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
I/O
41
EPM
I
42
CD MOTOR
I/O CD motor control
43
NC
-
44
CD DISC12 SW
I
45
NC
-
46
VFD CE
O
47
NC
-
48
ROTARY CCW
I
49
ROTARY CW
I
50
NC
-
51
RDS DATA
I/O RDS decoder data input
52
RDS QUAL
I
53
CD MUTE
I
54
S SOC REQ
I
55
SOC RST
O
56
SOC S STOP
O
57
S SYS REQ
O
58~61
NC
-
62
VCC2
-
63
NC
-
64
VSS
-
65
RDS NOISE
I
66
TUN SMETER
I
67
TUN IFC OUT
I
68
AUD DC ERR
I
69
LX RST
O
70
LX CON
O
71
LX MUTE
I
72
LX REQ M
O
73
PWIC SVR
O
74
RDS CLK
I/O RDS decoder clock input
75
LX REQ S
I
76
PWIC STBY
O
77
PWIC MUTE
O
Application
Flash ROM EPM input
Not used
12cm disc detection
Not used
VFD control request
Not used
VOL key input (Counter-clockwise)
VOL key input (Clockwise)
Not used
RDS decoder QUAL input
CD mute request
Communication request from SOC to system
μ-COM
SOC reset
SOC stop
Communication request from system μ-COM
to SOC
Not used
Not used
FM noise detection
S-meter input
Front-end IFC-OUT input
DC offset detection
Forced reset to slave unit
Start-up request to slave unit
Mute request from slave unit
Communication request to slave unit
SVR discharge circuit
Communication request from slave unit
Power IC standby control
Power IC mute
KDC-W4044UA/W4044UAY/W4044UG/W4044UGY
KDC-W413UA/W413UAY/W4544U/W4644UY
Truth Value
Processing Operation Description
Table
L: Possible to rewrite fl ash ROM
Connects to VSS (Never set it to output Hi)
q
Refer to the truth value table
Output L fi xed
Output L fi xed
Output L fi xed
Detects pulse width
Detects pulse width
Output L fi xed
H: Normal, L: Mute request
H: Normal, L: Reset
H: Normal, L: SOC stopped
Output L fi xed
Output L fi xed
H: Station detected, L: No station
If DC offset is detected 20 times in 100ms with
condition below 1.0V, it will be judged as DC offset
is detected.
H: Reset, L: Normal
H: Slave unit ON, L: Slave unit OFF
H: Mute ON, L: Mute OFF
During 500ms after power OFF or momentary
power-down: H, Since then: L
Power ON: H, Power OFF: L
STANDBY source or momentary power-down: L,
TEL mute: L
7

Hide quick links:

Advertisement

Table of Contents
loading