Sharp LC-37GP1U Service Manual page 31

Lcd color television
Hide thumbs Also See for LC-37GP1U:
Table of Contents

Advertisement

7.2. White balance adjustment
1. White balance adjustment
Adjustment item
Adjustment conditions
1
Setting
2
Automatic adjust-
[Command]
ment execution
Process mode
KRSW0001
KKT10037
Setting
KYOF0000
OSDS0001
SBSL0016
Multi-point adjustment
mode
MSET0001
Adjustment value initializa-
tion
MSET0004
Point 6
WBI60928
MG6G****
MG6B****
MG6R****
Point 5
WBI50800
MG5G****
MG5B****
MG5R****
Point 4
WBI40656
MG4G****
MG4B****
MG4R****
Point 3
WBI30528
MG3G****
MG3B****
MG3R****
Point 2
WBI20352
MG2G****
MG2B****
MG2R****
Point 1
WBI10184
MG1G****
MG1B****
MG1R****
Writing
MSET0003
For detailed adjustment procedure, refer to "Kameyama Model Integral Monitor WB
Adjustment Specifications V1.6".
1) Make the following settings for the set.
AV MODE: [DYNAMIC]
Backlight: +16
Active Backlight: OFF
Aging time: Min. 60 minutes
2) Connect the white balance adjustment tool to the set.
[Adjustment procedure]
1) Using the remote controller, transmit the "monitor adjustment process" code.
2) Set the 6th point to the specified gradation level. With the strongest color being fixed,
turn down the R, G and B settings to their reference levels.
3) Set the 5th point to the specified gradation level. Correct the G setting (800 x 6th-
point G setting / 928) (rounded off), and make the R and B settings to their reference
levels.
4) Set the 4th point to the specified gradation level. Correct the G setting (656 x 6th-
point G setting / 928) (rounded off), and make the R and B settings to their reference
levels.
5) Set the 3rd point to the specified gradation level. Correct the G setting (528 x 6th-
point G setting / 928) (rounded off), and make the R and B settings to their reference
levels.
6) Set the 2nd point to the specified gradation level. Correct the G setting (352 x 6th-
point G setting / 928) (rounded off), and make the R and B settings to their reference
levels.
7) Set the 1st point to the specified gradation level. Correct the G setting (184 x 6th-
point G setting / 928) (rounded off), and make the R and B settings to their reference
levels.
8) With the MSET0003 command, write the adjustment values and turn off the AC
power.
* Initial R, G and B settings at point 6: Gradation level set at 928
* Initial R, G and B settings at points 1 thru 5: Corrected G setting at each point
(This is because the adjustment is made to achieve the same remainder of RGB setting /
4 at each point.)
[Adjustment value]
•As per the "standard set" submitted by Engineering Department
"LC-32GP1U/LC-37GP1U" Teaching set
[Adjustment reference] Instrument: Minolta CA-210 Engineering instrument
Level
Reference
Point 6
928
X=0.272
y=0.277
Point 5
800
X=0.272
y=0.277
Point 4
656
X=0.272
y=0.277
Point 3
528
X=0.272
y=0.277
Point 2
352
X=0.272
y=0.277
Point 1
184
X=0.272
y=0.277
Note
Set conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Backlight: OFF
Aging Time: Min. 60 minutes
5 – 13
LC-32GP1U/LC-37GP1U 1st
Adjustment procedure
Adj. spec
±0.0025
±0.0025
±0.0025
±0.0035
±0.0060
±0.0100
Ins. spec
±0.003
±0.003
±0.003
±0.005
±0.010
±0.015

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-32gp1u

Table of Contents